Alarms: Firmware Versions 6.02 and Above
Alarms: Firmware Versions 6.02 and Above
Any time a Fault / Warning occurs, a combination of LED's will illuminate to notify you there is a problem and help
identify the kind of Fault / Warning has occurred. An error message will display and flash every 2 seconds for an
alarm, temperature or current warning and every 10 seconds for all other types of warnings.
•
Faults will not automatically clear.
•
To clear an fault, press and hold the RESET button on the display button pad for 3 seconds.
•
To clear a warning press and immediately release the RESET button.
Fault / Warning Scenarios
The following pages describe the most likely fault / warnings you could receive.
Alarm Type
Low Level
Warning
MM : SS
68
What it Looks Like
SS
##
HH
MM
!
ON
OFF
HH : MM
C
1
P
C
C
1 2 3
2
P
C
P
3
P
What it Indicates
Level of lubricant in
reservoir is low and addi-
tional lubricant needs to be
added.
Unit continues to operate
as normal for a limited
period of time until a low
level alarm is triggered or
until the reservoir is filled
and 30 seconds has
passed at which time the
warning will self-clear.
Solution
Add lubricant to reservoir.
After lubricant
is added,
press the
RESET but-
ton to clear the warning.
332305J