Fault/Warning Scenarios For Firmware Versions 6.06 And Later For Non-Dms Models And 7.09 And Later For Dms Models - Graco G3 Series Instructions Manual

Max automatic lubrication pump, for dispensing of nlgi grades #000 to #2 greases and oil with at least 40cst, for professional use only, not approved for use in explosive atmospheres or hazardous locations
Hide thumbs Also See for G3 Series:
Table of Contents

Advertisement

Fault/Warning Scenarios for Firmware Versions 6.06 and Later for Non-DMS Models and 7.09 and later for DMS Models

Fault/Warning Scenarios for Firmware Versions 6.06
and Later for Non-DMS Models and 7.09 and later for
DMS Models
Alarm Type
Low Power
Warning
HH
MM : SS
Low Power
Fault
HH
MM : SS
332305J
What it Looks Like
SS
##
MM
!
ON
OFF
HH : MM
C
1
P
C
C
1 2 3
2
P
C
P
3
P
MM
SS
##
!
ON
OFF
HH : MM
C
1
P
C
C
1 2 3
2
P
C
P
3
P
What it Indicates
If there is a voltage drop at
the power source during
operation, the pump will go
into a low power warning
condition.
The unit will continue to
operate for a total of 15
minutes before going into a
Low Power Fault.
Also if the pump power
cycles on power up for a
minimum of 3 times, the
pump will display a low
power warning.
If the warning condition
clears itself, the warning is
cleared and the unit contin-
ues operation.
There is a low voltage con-
dition at the power source.
Solution
Check voltage and avail-
able current output at the
power source of the
pump.
Check voltage and avail-
able current output at the
power source of the
pump.
Press and hold the
RESET button to clear
fault.