SECTION 2: INSTALLING THE ACCORD

Fixing the Enclosure

The two parts (lid and base) of the Accord control panel enclosure are connected
by:
• Five pillars on the enclosure lid with corresponding holes in the enclosure
base.
• A clip connection and fixing screw connection for the bottom of the enclosure
lid and base.
Note: Leave about 60 mm above the control panel enclosure to enable the enclosure
lid to move on its hinges for removal and replacement.
+
AUX
+
BELL
BELL
TAMP
–R
STRB
LS
TRIG
Vol
K'PAD
Use the keyhole slot in the enclosure base to position the control panel enclosure. All
cables should be brought into the enclosure base via the cable entry points shown in
Figure 2.2. There is a raised, outer, plastic rim with a number of snap-outs for the entry
of trunking. Once all cable entries have been made secure the control panel firmly in
place using the two mounting holes at the bottom of the control panel enclosure.
The user instructions can be held behind the enclosure using the User Instuctions
retaining clip, see Figure 2.2.
Aux F2
Batt F1
Bell F3
R47
SW1
ZONE
ZONE
ZONE
TAMP
1
1
Figure 2.1 Accord PCB Layout.
ZONE
ZONE
ZONE
ZONE
2
3
4
5
5
LED1
Q1
U1
ZONE
ZONE
ZONE
6
8
7
AC
AC
BAT+
BAT–
GND