1. Information before installing

1.1 General delivery terms and conditions

All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The latter must make
written reserves on the transporter's delivery documents if damage during transport is discovered (confirmed by
registered letter to the transporter within 48 hours).
The device must be transported and stored upright on its pallet in its original packaging.
If the appliance has been tipped over, make written reserves to the transporter.

1.2 Content

Power Force
x1

1.3 Technical specifications

Power Force
25
35
* with ambient air at +15 °C, pool water at 26 °C, and relative humidity of 70% (according to French standard NF-414)
Operating range:
• air temperature of between -12 °C and 38 °C,
• water temperature of between 10 °C and 32 °C,
Maximum temperature setting of 32°C to protect the pool lining.
The heat pump can de-ice by forced ventilation or a reverse cycle.
Fan speed will vary depending on ambient conditions.

2. Installation

Do not take grip on the outer casing to pick up the device, hold the base.

2.1 Selecting an installation site

The device must be installed outdoors and there must be adequate open space surrounding it (see §2.3).
• The heat pump must be installed at a minimum distance from the edge of the pool in order to avoid any projections of
spray onto the appliance. This distance is determined by the electric standards applicable locally.
• The heat pump must not be installed:
-
close to a heat source or to a source of inflammable gas,
-
close to a road with a risk of water or mud being sprayed,
-
facing strong winds,
-
with the blower facing a permanent or temporary obstruction (window, wall, hedge, etc.) less than 4 metres away.

2.2 Installing the appliance

• Fit the 4 anti-vibration pads (supplied, see §1.2)
• Install on a stable, solid surface (concrete slab for example) which is level,
• Protect from risks of flooding due to condensates from the appliance when it is running (see §2.3).
The heat pump can be fixed to the ground using the brackets at the base of the unit .
3
Wintering Cap
x2
Voltage
400V-50Hz
400V-50Hz
In a bag in the technical compartment
Anti-vibration pads
x4
Input power*
5.66 kW
7.50 kW
Fitting Ø63
x2
Rated input intensity*
10.6 A
12.9 A
H0361900.E - EN - 2015-02