2.4.4 Connecting options
Use cables with a cross-section: of 2 x 0.75 mm² or larger, of type RO2V or equivalent in countries outside of the European
Community, with an outer diameter of between 8 and 13 mm.
Remove the lid (just above the cable gland) and fit the supplied cable glands to run the cables into the device.
The cables used for the optional features and the power supply must be held together using a collar inside the
device, just after the cable gland.
Any incorrect connection to terminals 1 to 8 could damage the regulator and void the warranty.
Never supply the motor of the filter pump directly using terminals 1-2.
If orange terminals 1 to 8 are serviced, there is a risk of electrical return current, injuries, material damage and
death.
• «Heating priority»
- Function: servo function to control the filtration pump operation (by a minimum 5-minute cycle every hour, with
filtration maintained if the pool temperature is below the required temperature),
- Thanks to a dry contact (without max. I polarity = 8 A)
- Between terminals 1-2.
• Alarm
- Function: connect a relay to the alarm terminal,
- Thanks to a dry contact (without max. I polarity = 2 A)
- Between terminals 5-6.
• Remote on/off control
- Function: connect a remote «on/off» button
- Thanks to a zero-potential free contact, without 230 V - 50 Hz polarity, connect the cable to the busbar between
terminals 7-8,
- Activate the command by pressing
, then press 3 seconds on
pressing
:
A1-A2 : supply to the power contactor coil of the filter pump
B : filter timer
C : power contactor (3-pole or 2-pole), supplying the filter pump
D : independent connecting cable for the «heating priority» function
E : terminal
F : fuse
G : independent connecting cable for alarm contact relay
H : alarm contact relay
I : remote on/off switch
J : independent connecting cable for remote on/off control
• Remote control unit
- Function: control the heat pump remotely.
- Refer to the instructions for the remote control unit for connections.

3. Use

3.1 Presentation of the regulation

5
for 5 seconds when regulation is not on standby:
, press
to exit.
Cold mode
:
, select «Yes» using key
, then validate by
Water temperature
Setpoint temperature
H0361900.E - EN - 2015-02