Information Before Installing; General Delivery Terms And Conditions; Content; Technical Specifications - Zodiac Z300 Series Instructions For Installation And Use Manual

Table of Contents

Advertisement

1. Information before installing

1.1 General delivery terms and conditions

All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The latter must make
written reserves on the transporter's delivery documents if damage during transport is discovered (confirmed by
registered letter to the transporter within 48 hours).
The device must be transported and stored upright on its pallet in its original packaging.
If the appliance has been tipped over, make written reserves to the transporter.

1.2 Content

Z300
x1

1.3 Technical specifications

Z300
Voltage
M4
230V-50Hz
M5
230V-50Hz
T5
400V-50Hz
M7
230V-50Hz
MD5
230V-50Hz
TD5
400V-50Hz
MD8
230V-50Hz
TD8
400V-50Hz
* with ambient air at +15 °C, pool water at 26 °C, and relative humidity of 70% (according to French standard NF-414)
• class: I,
• degree of pollution: 2,
• overvoltage category: II
Operating range:
• air temperature of between 5 °C and 38 °C for standard models,
• air temperature of between -8 °C and 38 °C for D models,
• water temperature of between 10 °C and 32 °C,
Maximum temperature of 32°C to protect the pool liner.
The D version also features a de-icing function by using forced ventilation or reversed cycle.

2. Installation

Do not take grip on the outer casing to pick up the device, hold the base.

2.1 Selecting an installation site

The device must be installed outdoors and there must be adequate open space surrounding it (see §2.3).
• The heat pump must be installed at a minimum distance from the edge of the pool in order to avoid any projections
of spray onto the appliance. This distance is determined by the electric standards applicable locally (for France: 3.5
meters).
• The heat pump must not be installed:
-
close to a heat source or to a source of inflammable gas,
-
close to a road with a risk of water or mud being sprayed,
-
facing strong winds,
-
with the blower facing a permanent or temporary obstruction (window, wall, hedge, etc.) less than 4 metres away.
3
Wintering cover
x1
Wintering Cap
x2
Input power*
1.7 kW
2.2 kW
2.2 kW
2.88 kW
2.2 kW
2.2 kW
3.6 kW
3.6 kW
In a bag in the technical compartment
Fitting Ø50
x2
Rated input intensity*
7.9 A
10.3 A
4.25 A
13 A
10 A
4.4 A
16 A
7.4 A
H0439100.B - EN - 2014-09
Cable gland
x1

Advertisement

Table of Contents
loading