5.3 FAQ

Is it possible to
improve temperature
performance?
Why is my heat pump
not heating?
Where should my
water treatment
system be positioned
with respect to the
heating system?
The heat pump is
giving off water: is this
normal?

6. Registering the product

Register your product on our website:
-
be the first to be informed of new Zodiac® products and special offers,
-
help us to constantly improve our product quality.
Europe & Rest of the World
America
Australia – Pacific
H0361900.E - EN - 2015-02
In order to
• Protect the pool with a cover (floating cover, roller cover, etc.), to avoid
improve the
heat loss
efficiency of
• Choose periods when the outside temperature is warm (on average
> 10°C the night) in order to facilitate the temperature increase (this
your heat
pump it is
may take several days. The actual time will vary according to weather
recommended
conditions and the power of the heat pump)
that you:
• Keep the evaporator clean
Check that
• During the heating phase, water flow must be continuous (24/24)
filtration time
• To maintain the temperature throughout the season, allow for
is sufficient
"automatic" flow of at least 12 hours/day (the longer automatic flow is
used, the more time the heat pump will have to function and to heat the
water)
Setting the set-point to maximum will not heat the water any faster.
• On start-up the device remains on «pause» for 3 minutes before actually starting up: check
that this period has passed
• Once the pool has reached the set-point temperature, the heat pump switches off: check
that the water temperature is lower than the requested temperature (see §3.2)
• If the water flow-rate is zero or inadequate, the heat pump will stop: check that water is
flowing correctly through the heat pump, and check the hydraulic connections
• When the outside temperature drops below -12 °C, the heat pump will stop: check the
outdoor temperature
• The heat pump may have detected a malfunction: check if an error code is displayed on
the screen, if so refer to §5.1
• If the problem persists after you have checked all of the above points: contact your
installer
• The water treatment system (chlorinator, salt chlorinator, etc.) must be installed preferably
downstream from the heat pump (see installation §2.4), and must be compatible with the
latter (check with the manufacturer)
• Your heat pump will give off water in the form of condensation. This water is the humidity
contained in the air, which condenses on contact with certain cold components inside the
heat pump.
• Note: your device can produce several litres of water per day.