Zodiac PM40 Series Instructions For Installation And Use Manual

Zodiac PM40 Series Instructions For Installation And Use Manual

Advertisement

PM40
Instructions for installation and use -
English
EN
Heat pump
Translation of the original instructions in French
More documents on:
www.zodiac.com
H0686400_REVA - 2020/02

Advertisement

Table of Contents
loading

Summary of Contents for Zodiac PM40 Series

  • Page 1 PM40 Instructions for installation and use - English Heat pump Translation of the original instructions in French More documents on: www.zodiac.com H0686400_REVA - 2020/02...
  • Page 3 WARNINGS This symbol shows that This symbol shows that this information is available such appliance uses R32, a low as the Operating Manual or burning velocity refrigerant. Installation Manual. This symbol shows that a service This symbol shows that the personnel should be handling Operation Manual should be read this equipment with reference to...
  • Page 4 carrier. • If the appliance suffers a malfunction, do not try to repair it yourself; instead contact a qualified technician. • Refer to the warranty conditions for details of the permitted water balance values for operating the appliance. • Deactivating, eliminating or by-passing any of the safety mechanisms integrated into the appliance shall automatically void the warranty, in addition to the use of spare parts manufactured by unauthorised third-party manufacturers.
  • Page 5 • If the power cord is damaged, it must be replaced by the manufacturer, its technician or a qualified person to guarantee safety. • Do not perform maintenance or servicing operations on the appliance with wet hands or if the appliance is wet. •...
  • Page 6 must be checked, as well as the absence of any traces of refrigerant. • During the appliance's annual sealing test in accordance with applicable legislation, the high and low pressure switches must be checked to ensure that they are securely fastened to the cooling circuit and that they cut off the electrical circuit when tripped.
  • Page 7 Check for the presence of refrigerant • The area must be analysed using a suitable refrigerant detector before and during work so that the technician is informed of the presence of a potentially toxic or flammable atmosphere. Check that the leak detection equipment used is suitable for use with all refrigerants concerned, i.e.
  • Page 8 if maintenance work must continue, an appropriate temporary solution must be found. This must be reported to the equipment's owner so that all persons concerned are made aware. • The repair and maintenance of electric components must include the following initial safety checks: - the capacitors are discharged: this must be carried out safely to prevent all risks of ignition;...
  • Page 9 • Electronic leak detectors can be used to detect refrigerant leaks; however, in the case of flammable refrigerants, the sensitivity level may not be suitable or recalibration may be necessary. (The detection equipment must be calibrated in an area devoid of refrigerant). Check that the detector is not a potential ignition source and is appropriate for the refrigerant used.
  • Page 10 The system must be examined to make sure there are no leaks after the charging operation and before commissioning. A follow-up leak test must be carried out before leaving the site. Dismantling • Before dismantling, the technician must familiarise himself/herself with the equipment and its specifications.
  • Page 11 refrigerant. The cylinders must be equipped with a vacuum valve and a stop gate in good working order. Empty collection cylinders are drained and, where possible, cooled before recovery. • The recovery equipment must be in good working order, the instructions for using the equipment must be within reach and the equipment must be compatible for use with the refrigerant concerned, including, where appropriate, a flammable refrigerant.
  • Page 12: Table Of Contents

    • The distribution or modification of this document in any way is prohibited, without prior authorisation from Zodiac®. • Zodiac® is constantly developing its products to improve their quality. The information contained herein may therefore be modified without notice. CONTENTS ❶...
  • Page 13: ❶ Installation

    ❶ Installation 1.1 I Selecting the location • When the appliance is installed and protected by a residual current device (RCD) with a maximum amperage of 30 mA, it should be installed at a distance of at least 2 metres from the edge of the pool.
  • Page 14: I Hydraulic Connections

    1.2 I Hydraulic connections • The device will be connected with a Ø1.5" PVC pipe, using the connectors supplied (see § "5.1 I Description"), to the pool's filtration circuit, after the filter and before the water treatment system. • Respect the direction of hydraulic connection. •...
  • Page 15: I Accessing The Electrical Terminal Blocks

    1.3 I Accessing the electrical terminal blocks Unscrew the 2 screws in the top right Unscrew the 4 screws from the Pass the cables through the cable of the appliance and remove the top housing protecting the electrical gland at the rear of the appliance. part.
  • Page 16: I Option Connections

    1.5 I Option connections Connecting "Heating Priority" options: • Before any work inside the appliance, you must cut the appliance’s electricity supply as there is a risk of electric shock which may cause material damage, serious injury or even death. •...
  • Page 17: ❷ Use

    ❷ Use 2.1 I Operating principle 2.1.1 General operation Your heat pump uses the calories (heat) in the air to heat up your pool's water. The process to heat your pool's water to the temperature you want may take a few days as it depends on the weather conditions, the heat pump's power and the difference between the water temperature and the temperature you want.
  • Page 18: I Operation

    Description Steady Flashing Operating in "HEATING" "HEATING" mode Time delay Mode disabled mode Operating in "COOL- "COOLING" mode Time delay Mode disabled ING" mode "HEATING & COOLING" Operating in "HEATING Time delay Mode disabled mode & COOLING" mode Alarm Alarm enabled Disabled Padlock Keypad locked...
  • Page 19: I User Functions

    2.4 I User functions 2.4.1 "Automatic keypad lock" function The "automatic keypad lock" function allows the keypad to be disabled when inactive for a certain period of time to prevent mishandling. Locking/unlocking the keypad: • Press simultaneously for 5 seconds. indicator appears (= locked) or disappears (= unlocked) depending on the keypad's state.
  • Page 20 2.4.4 Setting the time • Press for 5 seconds to set the time. The hours flash to show that they can now be changed. • Set the hours using the keys. • Press to confirm the hours setting. Once the hours have been confirmed, the minutes begin to flash. •...
  • Page 21: ❸ Maintenance

    • Clean the outside of the appliance using a solvent-free product; a specific "PAC NET" cleaning kit is available as an accessory in the Zodiac® catalogue for this purpose (see § "5.1 I Description"). 3.2.2 Maintenance to be carried out by a qualified technician •...
  • Page 22: ❹ Troubleshooting

    ❹ Troubleshooting • If a problem occurs, before you contact your retailer, please carry out these few simple checks using the following tables. • If the problem continues, contact your retailer. • : Actions to be performed by a qualified technician only 4.1 I Appliance behaviour •...
  • Page 23: I Error Code Display

    4.2 I Error code display Display Possible causes Solutions Sensor disconnected or out of order. Reconnect or replace the sensor. Faulty inlet water temperature sensor Sensor disconnected or out of order. Reconnect or replace the sensor. Faulty outlet water temperature sensor Sensor disconnected or out of order.
  • Page 24: I Wiring Diagrams

    4.3 I Wiring diagrams 4.3.1 PM40 MD1 Symbol Description 4-way valve Vanne 4 voies Condenser electric heater Chauffage électrique du condenseur NOTE: For water pump currents exceeding 1.5 Amp, NOTE: Pour le courant de la pompe à eau au-dessus de 1,5 Amp. please provide a suitable external A/C contactor.
  • Page 25 4.3.2 PM40 MD2 - MD3 - MD4 - MD5 Symbol Description 4-way valve Vanne 4 voies Condenser electric heater Chauffage électrique du condenseur NOTE: For water pump currents exceeding 1.5 Amp, NOTE: Pour le courant de la pompe à eau au-dessus de 1,5 Amp. please provide a suitable external A/C contactor.
  • Page 26 4.3.2 PM40 MD7 - MD8 Symbol Description 4-way valve Vanne 4 voies Condenser electric heater Chauffage électrique du condenseur NOTE: For water pump currents exceeding 1.5 Amp, NOTE: Pour le courant de la pompe à eau au-dessus de 1,5 Amp. please provide a suitable external A/C contactor.
  • Page 27 4.3.2 PM40 TD7 - TD8 Symbol Description 4-way valve Vanne 4 voies Condenser electric heater Chauffage électrique du condenseur NOTE: For water pump currents exceeding 1.5 Amp, NOTE: Pour le courant de la pompe à eau au-dessus de 1,5 Amp. please provide a suitable external A/C contactor.
  • Page 28 4.3.2 PM40 TD12 Symbol Description 4-way valve Vanne 4 voies Condenser electric heater Chauffage électrique du condenseur NOTE: For water pump currents exceeding 1.5 Amp, NOTE: Pour le courant de la pompe à eau au-dessus de 1,5 Amp. please provide a suitable external A/C contactor. S’il vous plaît équiper l’extérieur A/C contacteur approprié.
  • Page 29: ❺ Specifications

    ❺ Specifications 5.1 I Description PM40 1.5" PVC connectors Anti-vibration pads Winterising cover Heating priority Remote control kit PAC NET (cleaning product) : Included : Available as an accessory...
  • Page 30: I Technical Specifications

    5.2 I Technical specifications PM40 TD12 -8 to 38 °C Operating temperatures water 8 to 40 °C Power output* 10.5 11.7 14.7 17.7 22.5 18.5 22.1 Voltage 220-240V / 50 Hz / 1PH 380-415V / 50 Hz / 3PH Admissible variation in voltage ±...
  • Page 31: I Dimensions And Marking

    5.3 I Dimensions and marking MD1 - MD2 - MD3 - MD4 - MD5 - MD7 - TD12 MD8 - TD7 - TD8 Front : Air outlet : User interface : Pool water inlet : Pool water outlet : Evaporator Side Rear PM40...
  • Page 32 Your retailer Modèle appareil Appliance model Numéro de série Serial number Pour plus d’informations, enregistrement produit et support client : For more information, product registration and customer support: www.zodiac.com ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.

Table of Contents