    1. Installation .................... 2   1.1 Generals ......................2   1.1.1 Cautions ........................2  1.1.2 General terms of delivery ................... 2  1.1.3 Storage and transport conditions ................3  1.1.4 Field of application ..................... 3  1.1.5 How it works ....................... 3  1.2 Technical characteristics ..................
  • Page 3: Installation

    1. Installation 1.1 Generals Carefully read this manual before installing, performing maintenance on or troubleshooting this device! The symbol indicates the presence of important information that must be taken into account to avoid injurying people or damaging the device. The symbol indicates the presence of useful information serving as a guideline.
  • Page 4: Storage And Transport Conditions

    1.1.3 Storage and transport conditions The appliance must be transported upright on its pallet. 1.1.4 Field of application Exclusive use: heating swimming pool water It must not be used for anything else. 1.1.5 How it works Compressor Water 28 °C Air 15 °C Air 10 °C Water 26 °C...
  • Page 5: Installation

    1.4 Installation Do not pick up the unit by the outside case, use the base to lift the unit. The installation and the hydraulic and electrical connections must be done to standards in force. 1.4.1 Access to technical compartment 1.4.2 Selection of installation site The appliance must be installed outdoors and must be surrounded by free space (see §1.4.4).
  • Page 6: Hydraulic Connections

    1.4.4 Hydraulic connections The water treatment system (chemical or electro-physical disinfection) must be installed downstream from the heat pump (see installation below), and must be compatible with it (check with the manufacturer).  The connection shall be by Ø 50 PVC pressure pipe, from a by-pass , to the swimming pool filter ...
  • Page 7: Electric Connections

    If the power cable is damaged, it must be replaced by a qualified technician or in a Zodiac Pool Care Europe technical station. 1.4.5.3 Cable sections supply cable section: for cables of a maximum length of 20 metres (calculation base: 5A/mm²), ...
  • Page 8 Main advantages offered by this function: - a guarantee that the heat pump operates long enough to attain the required temperature, in particular during initial warm-up periods (no longer necessary to manually switch on the filter system 24h/24). - constant control and monitoring of the pool heating requirements, even when the filter system has been switched off by the timer.
  • Page 9: Starting Up

    1.5 Starting up 1.5.1 Presentation of the regulation : controller “on” indicator : priority heating output enabled indicator : “on/off” or stand-by : compressor “on” (steady) or timed (blinking) indicator : display required water temperature or setting : defrost in progress (steady) or : setting values timed (blinking) indicator 1.5.2 Checks before operating the appliance...
  • Page 10: Checking

     switch on the electrical supply to the heat pump, When the regulator is first switched on, the following information messages appear: “REXX” then “MAPX”.  if the heat pump is in stand-by: , press 3 seconds on appears for 5 seconds and then the water temperature is displayed.
  • Page 11: Troubleshooting

    2. Troubleshooting 2.1 Statuses and faults of the regulator 2.1.1 Statuses The indicator remains on for 2 minutes after the message Display Cause Solution Reset 1 - filtration pump off 1- clean the filter and start the filtering 2 – water flow in the 2- check the adjustment of the valves, Automatic appliance not enough,...
  • Page 12: Display The Values Of Sensors St1-St2-St3 And St4

    Display Designation Cause Solution Reset Switch the power Water flow- Sensor defective or Replace or supply off and then rate sensor disconnected reconnect the back on again or fault (terminals 4-5 of the (alternating with sensor automatic if the (ST4) plate B1) fault disappears.
  • Page 13: The Appliance Operates But The Water Temperature Does Not Rise

    2.2.2 The appliance operates but the water temperature does not rise Causes Verification / solution Put the filtering on manual 24/24 hours to raise Not enough filtering time the temperature. Check whether the heat pump is of the right Non-complying period of use dimension for this period of the year.
  • Page 14: Available Accessories

     check that all metal elements are earthed,  clean the outside of the unit with a solvent-free product. A specific PAC NET cleaning kit is available as an optional extra (see §3.2),  check that the condensation is flowing out properly whilst the appliance is operating. 3.2 Available accessories Naming Representation...
  • Page 15: Recording On Line

    5. Recording on line Register your product on our website: - you will be the first to be informed of new Zodiac products and special offers, - You can help us to constantly improve our product quality. Australia – New Zealand www.zodiac.com.au...
  • Page 16: Repair

     the person responsible for final acceptance of the unit must carry out a visual inspection to detect any damage the unit may have suffered during transport: refrigeration circuit, electrical enclosure, frame and casing.  the unit may not be installed close to: - a heat source, - combustible materials, - the air duct inlet of an adjacent building.
  • Page 18: Electric Diagram

    Electric diagram PF 6M-8M...
  • Page 19 PF 11M-13M-15M...
  • Page 20: Dimensions And Description

    Dimensions and description Weight (Kg)
  • Page 21                English  Base  Front pannel  cowl  Technical door  Back pannel  Post  Grid  Regulator  Ø1” ½ water pool inlet ...
  • Page 24 Plaque signalétique – Product name plate Votre installateur – Your installer Zodiac Pool Care Europe – BP 90023 49180 Saint Barthélémy d’Anjou cedex – France www.zodiac-poolcare.com Innovative pool products and services Produits et services innovants pour la piscine...

This manual is also suitable for:

Fp 8m

Table of Contents