Dysfunction 
the heat pump makes 
trip the circuit breaker 
 
5.3 FAQ 
 
Is it possible to 
In order to 
improve 
improve the 
temperature 
efficiency of 
performance? 
your heat 
pump it is 
recommende
d that you: 
Check that 
filtration 
time is 
sufficient  
Setting the set‐point to maximum will not heat the water any faster 
Why is my heat 
on start‐up the device remains on "pause" for 3 minutes before actually starting up: check 
pump not 
that this period has passed 
heating? 
once  the  pool  has  reached  the  set‐point  temperature,  the  heat  pump  switches  off:  check 
that the water temperature is lower than the requested temperature (see §3.2) 
if  the  water  flow‐rate  is  zero  or  inadequate,  the  heat  pump  will  stop:  check  that  water  is 
flowing correctly through the heat pump, and check the hydraulic connections 
when the outdoor air temperature drops below ‐12 °C, the heat pump will stop: check the 
outdoor temperature 
the heat pump may have detected a malfunction: check if an error code is displayed on the 
screen, if so refer to §5.1  
If the problem persists after you have checked all of the above points: contact your installer 
Where should 
The water treatment system (chlorinator, salt chlorinator, etc.) must be installed preferably 
my water 
downstream from the heat pump (see installation §2.4), and must be compatible with the 
treatment 
latter (check with the manufacturer) 
system be 
positioned with 
respect to the 
heating system? 
The heat pump is 
Your heat pump will give off water in the form of condensation. This water is the humidity 
giving off water: 
contained in  the air, which condenses on contact with certain  cold components inside the 
is this normal? 
heat pump.  
Warning: your device can produce several litres of water per day. 
 
6. Product registration 
 
Register your product using our website:  
- you will be among the first to be informed of new Zodiac products and special offers, 
- You can help us to constantly improve our product quality. 
 
 
 
 
 
 
 
 
 
 
H03620‐00.B5.EN – 2011/11
Causes 
The circuit breaker rating is too low or 
inappropriate 
The cable cross‐section is too small 
The supply voltage is too low 
protect the pool with a cover (floating cover, roller cover, etc.), to avoid heat 
loss 
choose periods when the outside temperature is warm (on average > 10° C) 
in  order  to  facilitate  the  temperature  increase  (this  may  take  several  days. 
The actual time will vary according to weather conditions and the power of 
the heat pump) 
the  higher  the  ambient  air  temperature,  the  more  efficient  the  heat  pump 
will be 
keep the evaporator clean 
during the heating phase, water flow must be continuous (24/24) 
to maintain the temperature throughout the season, allow for "automatic" 
flow of at least 12 hours/day (the longer automatic flow is used, the  more 
time the heat pump will have to function and to heat the water) 
Australia – New Zealand 
South Africa 
Europe and rest of the world 
 
Verification / solution 
Check the circuit breaker (see § 2.5.3). 
Check the cable cross‐section (see § 2.5.3) 
Call your electricity provider 