1xxx
Reference Code
Description/Action Perform all actions before exchanging Failing Items
6818
One of the regulators has reported a fault
A fault detection failure occurred for a regulator. The regulator or the ac
module/SPCN card can cause this fault.
6918
One of the regulators has reported a fault
An over current fault detection failure occurred for a regulator. The
regulator or the ac module/SPCN card can cause this fault.
6A18
Regulator Fault
A regulator fault detection failure occurred for regulator 1. The ac module
or the regulator can cause this fault.
6A38
Regulator Fault
A regulator fault detection failure occurred for regulator 2. The regulator or
the ac module/SPCN card can cause this fault.
6A58
Regulator Fault
A regulator fault detection failure occurred for regulator 3. The regulator or
the ac module/SPCN card can cause this fault.
6B00
Disk Unit 1 regulator fault
The regulator that powers disk unit 1 reported a fault.
6B01
Disk Unit 2 regulator fault
The regulator that powers disk unit 2 reported a fault.
6B02
Disk Unit 3 regulator fault
The regulator that powers disk unit 3 reported a fault.
6B03
Disk Unit 4 regulator fault
The regulator that powers disk unit 4 reported a fault.
6B04
Disk Unit 5 regulator fault
The regulator that powers disk unit 5 reported a fault.
6B05
Disk Unit 6 regulator fault
The regulator that powers disk unit 6 reported a fault.
6B06
Disk Unit 7 regulator fault
The regulator that powers disk unit 7 reported a fault.
6B07
Disk Unit 8 regulator fault
The regulator that powers disk unit 8 reported a fault.
6B08
Disk Unit K1 regulator fault
The regulator that powers disk unit K1, located in slot K1 of the disk
expansion unit, reported a fault.
6B09
Disk Unit K2 regulator fault
The regulator that powers disk unit K2, located in slot K2 of the disk
expansion unit, reported a fault.
36
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)
Failing Item
PWRREG
BKSPCN
PWRREG
BKSPCN
PWRREG
BKSPCN
BACKPLN
PWRREG
BKSPCN
BACKPLN
PWRREG
ACMODUL
BACKPLN
DISKTRY
DISKDRV
BKSPCN
DISKTRY
DISKDRV
BKSPCN
DISKTRY
DISKDRV
BKSPCN
DISKTRY
DISKDRV
BKSPCN
DISKTRY
DISKDRV
BKSPCN
DISKTRY
DISKDRV
BKSPCN
DISKTRY
DISKDRV
BKSPCN
DISKTRY
DISKDRV
BKSPCN
DISKTRY
DISKDRV
BKSPCN
DISKTRY
DISKDRV
BKSPCN

Advertisement