Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 11

Hide thumbs Also See for iSeries Series:

Advertisement

Reference Code
Description/Action Perform all actions before exchanging Failing Items
1110 to 1113
Failure of CEC power supply not identified by SPCN.
This reference code can be caused by something holding the system Power
On Reset (POR) line active.
1114
Failure of CEC power supply not identified by SPCN.
This reference code can be caused by something holding the system Power
On Reset (POR) line active.
2222
Service processor failure caused machine check interrupt.
Before exchanging the TWRCARD, remove the adapter cards from the
TWRCARD and perform an IPL. If the IPL completes successfully, one of
the adapter cards you removed is defective.
3333
SPCN to CSP interface error.
An attempt to communicate between the SPCN and the CSP processor
failed.
3334
CSP to VPD Collector interface error.
An attempt to communicate between the CSP and the VPD Collector failed.
4444
Power on request failure
A power-on request was not completed successfully. A control
panel-detected power-on failure occurred.
5553
Incorrect key used or the key is not completely inserted
The key inserted is not the correct key or is not completely inserted.
AABB
Remote power-on failure
An attempt was made to power on the system by a remote power-on
operation with the keylock mode on the control panel set to Secure or
Manual. To correct the problem, select Normal or Auto mode on the control
panel and perform the remote power-on operation again, if necessary.
AACC
Service processor power-on failure
An attempt was made to power on the system from the service processor
with Secure or Manual mode selected on the control panel. To correct the
problem, select Normal or Auto mode on the control panel and perform
the service processor power-on operation again, if necessary.
Note: This reference code may occur if the service processor card was
exchanged and Manual mode was selected. Select Normal mode on the
control panel.
AADD
Manual power-on failure
An attempt was made to power on the system manually with Secure or
Auto mode selected on the control panel. To correct the problem, select
Manual or Normal mode on the control panel and manually power on the
system again.
AAEE
SPCN - control panel interface error.
An attempt was made to power on the system from the SPCN with Secure
or Manual mode selected on the control panel. To correct the problem,
select Normal or Auto mode and attempt the remote power-on operation
again. If this does not correct the problem, exchange the failing items.
0000
Failing Item
TWRCARD
ANYBUS
TWRCARD
CTLPNL
ANYBUS
TWRCARD
ANYBUS
TWRCARD
TWRCARD
TWRCARD
BACKPLN
CTLPNL
TWRCARD
USER
TWRCARD
CTLPNL
USER
CTLPNL
TWRCARD
USER
CTLPNL
USER
CTLPNL
TWRCARD
7
System Reference Codes

Advertisement

loading