2749, 2767, 2768, 2842, 2843, 2844, 284B, 284C, 284D, 284E, 286C, 286D, 286E, 286F, 5702
Failing Item
Description
CMPRES1
Compressed device and compression IOA are
not compatible
CTLPNL
Control panel, or the interface to the Control
panel
DEVBPLN
Device backplane
DEVTERM
Terminating plug
FCIOA
Fibre Channel IOA
IOACNFG
Configuration error
IOP
I/O processor card
MA_BRDG
Multi-adapter bridge
MEDIA
Defective media
OPT_CLN
Fiber optic cleaning kit
PCIBUS
Any PCI card on the PCI bus
STORIOA
Storage I/O adapter
SVCDOCS
Customer engineer directed to system problem
analysis
USER
System Operator/User
(2765, 2766, 2787, 5704) Reference Codes
If the error is reported on the control panel, the unit reference code is characters 5
through 8 of the top 16 character line of function 11. If the error is reported on the
console, the unit reference code is the 4 rightmost characters of word 1.
Find the unit reference code in the following table.
For more on the Failing Item column entries, see Table 2. Failing Items Details,
which follows the reference code table below.
Table 1. (2765, 2766, 2787, 5704) Reference Codes
Reference Code
Description/Action Perform all actions before exchanging Failing Items
3020
I/O processor detected a configuration error
Either too many devices or the wrong kind of devices have been
configured under the IOA. Change the configuration.
3100
I/O processor card detected interface error
3120
I/O processor detected a port failure
3140
I/O Processor detected that a port is now operational
This reference code and the 3120 reference code that occurred before it
require no service action, since the port is now operational.
154
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)
Document Description
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Failing Item
SVCDOCS
FCINTF
ANYFC
FCIOA
OPT_CLN
FCPORT
FCIOA
FCDEV
OPT_CLN

Advertisement