Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 231

Hide thumbs Also See for iSeries Series:

Advertisement

Reference Code
Description/Action Perform all actions before exchanging Failing Items
3113
A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Read and understand the information about logical partitions.
See the iSeries Service Functions information.
Look in the Service Action Log of the Primary partition for B600xxxx SRCs
that were logged when the secondary partition was IPLing. Correct the
B600xxxx problem, then retry the secondary partition IPL.
If there are no B600xxxx SRCs in the Service Action Log of the Primary
partition from the secondary partition's IPL then contact your next level of
support.
3114
A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Read and understand the information about logical partitions.
See the iSeries Service Functions information.
Look in the Service Action Log of the Primary partition for B600xxxx SRCs
with the same bus/board/card numbers identified in the B2xx xxxx SRC
words. Use the new SRC and go to RCT.
The B2xx xxxx SRC Format is Word 1: B2xx3114, Word 3: Bus, Word 4:
Board, Word 5: Card.
3120
A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Retry count exceeded. Contact your next level of support.
3123
A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Due to the multi-adapter bridge configuration the IOA with the
load source device for the secondary partition does not belong to the IOP it
was assigned to when the secondary partition was configured.
Contact your next level of support.
3125
A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Read and understand the information on logical partitions. See
the iSeries Service Functions information.
Primary partition main store utilization problem. The Primary partition
code could not obtain a segment of main storage within the Primary
partition's main store to use for managing the creation of a secondary
partition.
3128
A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. An unexpected failure return code was returned when
attempting to query the IOA slots that are assigned to an IOP.
B2xx
Failing Item
LPARSUP
FI00096
LPARSUP
LPARSUP
LPARCFG
FI00099
227
System Reference Codes