432x, 660x, 671x, 673x
Reference Code
Description/Action Perform all actions before exchanging Failing Items
FFFB
SCSI bus reset occurred
No action required. This reference code is logged for information only.
FFFE
Temporary disk bus error
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see "Hardware Service Manager" in the iSeries Service
Functions.
Table 2. Disk Unit Failing Items Details
Failing Item
Description
BACKPLN
Card enclosure or backplane
CMPRES1
Compressed device and compression IOA are
not compatible
DEVTERM
Device terminator
DISKDRV
Disk drive and logic card
STORIOA
Storage I/O adapter
SVCDOCS
Customer engineer directed to system problem
analysis
(632x, 6330, 6336) Optical Storage Unit Reference Codes
An optical storage unit failure occurred.
Notes:
1. If the system is available, use online diagnostic tests when possible.
2. Search the problem log (WRKPRB) for a recent optical storage entry that may
3. Use the Hardware Service Manager (HSM) verify function (via DST or SST)
Perform the following:
1. If the system is available, attempt the failing operation again with an optical
For more on the Failing Item column entries, see Table 2. Optical Storage Unit
Failing Items Details, which follows the reference code table below.
Table 1. (632x, 6330, 6336) Optical Storage Unit Reference Codes
174
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)
assist in analyzing the problem. The WRKPRB entry will provide a unit
reference code that can be found in the following table.
and verify that the unit is operating correctly.
media that is known to be good.
Does the operation complete successfully?
v Yes: The original optical media may be defective, or the problem may be
intermittent.
Attempt the failing operation again with the original optical media to verify.
This ends the procedure.
v No: Look at the 4 rightmost characters of the Data display for word 1. These
4 characters are the unit reference code. Find the unit reference code in the
following table.
Document Description
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Failing Item
DISKDRV
STORIOA
FI01106
FI01140

Advertisement