Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 299

Hide thumbs Also See for iSeries Series:

Advertisement

Reference Code
Description/Action Perform all actions before exchanging Failing Items
7102
APPN CP-CP session ended.
7201
A utility failure occurred.
This reference code is for information only. The Uninterruptible Power
System (UPS) is reporting a utility failure.
7202
Utility power restored.
This reference code is for information only. The Uninterruptible Power
System (UPS) is reporting that utility power has been restored.
7203
A battery low condition was detected.
This reference code is for information only. The Uninterruptible Power
System (UPS) is reporting a battery low condition.
7204
Uninterruptible Power System reported a bypass active
This reference code is for information only. The Uninterruptible Power
System (UPS) is reporting a bypass is active.
7205
Battery low condition was reset.
This reference code is for information only. The Uninterruptible Power
System (UPS) is no longer reporting a battery low condition.
7206
UPS reported bypass no longer active
This reference code is for information only. The Uninterruptible Power
System (UPS) is no longer reporting a bypass active condition.
7207
Battery Power Unit needs service
The replacement period for BPU 1, installed in the System Unit, has been
exceeded.
7208
Battery Power Unit needs service
The replacement period for BPU 2, installed in the System Unit, has been
exceeded.
7209
Battery Power Unit needs service
The replacement period for BPU 1, installed in the Expansion Unit, has
been exceeded.
720A
Battery Power Unit replacement dates do not match
The replacement dates for one of the Battery Power Units do not match.
Run "Display Hardware Configuration" and verify that the dates match the
labels on the batteries.
7701
SCSI jumper card was not detected.
7702
Incorrect SCSI jumper card detected
7703
System LIC detected a program exception
Storage Management detected a DASD datacheck condition and the
defective sector was reallocated.
Perform a system IPL to restart the system.
7704
General failure detected by HRI component.
B6xx (including A6xx)
Failing Item
FI00315
FI00315
FI00315
21H7625
BACKPLN
21H7625
AJDG301
295
System Reference Codes

Advertisement

loading