Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 118

Hide thumbs Also See for iSeries Series:

Advertisement

1xxx
Reference Code
Description/Action Perform all actions before exchanging Failing Items
9103
Download Initialize Timeout
An SPCN node failed to enter the download state after an Initialize for
Download command.
Exchange the failing SPCN node.
9104
Download Completion Timeout
An SPCN node failed to leave the download state.
Exchange the failing SPCN node.
9105
Load Damaged Timeout
An SPCN node failed to enter the operational state.
Exchange the failing SPCN node.
9106
An SPCN LID was not found.
No action required. This reference code is logged for information only.
9107
An SPCN microcode download is required.
No action required. This reference code is logged for error analysis only.
9108
A status change occured in one of the SPCN nodes.
No action required. This reference code is logged for information only.
9109
Licensed Internal Code part number is not correct.
The AROS part number field was not updated to the correct level after the
system attempted to load new Licensed Internal Code.
9110
Battery Power Unit capacity test failed.
The battery power unit was not able to pass the capacity test.
9111
SPCN is too large for VLIC.
There are more nodes in the network than VLIC can service.
9112
Primary SPCN node is reporting load damaged.
The Licensed Internal Code for the primary SPCN node is damaged. The
reload failed because the code could not be found.
9113
Secondary SPCN node is reporting load damaged.
The Licensed Internal Code for the secondary SPCN node is damaged. The
reload failed because the code could not be found.
9114
Frame SPCN node is reporting load damaged.
The Licensed Internal Code for a SPCN node is damaged. The reload failed
because the code could not be found.
9115
SPCN Command rejected by the Service Processor.
The service processor rejected an SPCN command from the Licensed
Internal Code.
No action required. This reference code is logged for information only.
9116
SPCN - Control Panel interface failure.
The SPCN to control panel interface is not working.
114
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)
Failing Item
TWRCARD
TWRCARD
TWRCARD
TWRCARD
BATRY
AJDG301
TWRCARD
TWRCARD
TWRCARD

Advertisement

loading