Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 185

Hide thumbs Also See for iSeries Series:

Advertisement

For more on the Failing Item column entries, see Table 2. Workstation Adapter
Console Failing Items Details, which follows the reference code table below.
Table 1. (6A59) Workstation Adapter Console Reference Codes
Reference Code
Description/Action Perform all actions before exchanging Failing Items
0AD2 to 0AD3
Communications adapter card test failed
0B25
Communications adapter card test failed
0BA0, 0BAB, 0BB0,
Communications adapter card test failed
0BD0 to 0BD1
0BEE
I/O card Licensed Internal Code ended abnormally
0C10
Communications adapter card test failed
0C20
Communications adapter card test failed
0C30
Adapter card failed modem interface test
0C40, 0C43
Synchronous-data-link-control send-receive test failed
0C50, 0C53
Binary synchronous control send-receive test failed
0C60, 0C63
Asynchronous send-receive test failed
0C70, 0C80
Communications adapter card test failed
0C90
Communications adapter card X.21 test failed
0CA1, 0CC0
Communications adapter card test failed
5007
Diagnostic wrap test completed; no errors detected
5008
Diagnostic wrap test completed; error was detected
FFFF
User suspected communications problem.
Table 2. Workstation Adapter Console Failing Items Details
Failing Item
Description
DPAC
Communications two-port adapter cable
UNAUPPR
User suspected problem
(7208) Tape Drive Reference Codes
An 8mm tape drive failure occurred.
Note: For tape device and IOP reset procedures, see TU-PIP4.
Document Description
Problem Analysis; Symbolic FRU Isolation
System Reference Codes
6A59
Failing Item
FI00718
FI00719
FI00718
FI00727
FI00719
FI00718
FI00719
FI00718
FI00719
FI00718
FI00727
FI00719
FI00718
FI00719
FI00718
FI00719
FI00718
FI00719
FI00718
FI00719
FI00718
FI00719
FI00718
FI00719
FI00718
FI00719
FI00718
FI00719
DPAC
FI00718
UNAUPPR
181