Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 277

Hide thumbs Also See for iSeries Series:

Advertisement

Reference Code
Description/Action Perform all actions before exchanging Failing Items
512E
System LIC program exception occurred
The system was in a D IPL mode when the problem was detected. A main
storage dump was not taken.
Perform LIC-PIP1.
5206
System LIC detected a missing IOP LIC code load
System LIC detected a missing IOP LIC code load during IPL of the IOP.
This indicates that either the IOP code load is not installed on the system
load source device or that system LIC was unable to successfully read that
load from the load source device.
Perform LIC-PIP1.
5209
System LIC detected an IOP timeout during IOP IPL
Verify that all IOP cable connections are secure, and check tape and other
non-disk devices and media to verify that they are in a ready state.
Perform LIC-PIP1.
5219
System LIC program exception occurred
An IOP signalled to system LIC that it had entered a critical internal state.
LIC automatically attempted to restart the IOP.
This reference code is logged for information only. No action is required.
5275
The system issued a reset/reload to the IOP.
System Licensed Internal Code detected that an IOP Reset/Reload has
occurred, and that the IOP sucessfully recovered.
Users who were signed on to a Workstation device under the IOP will need
to sign back on. Any LAN/WAN communications lines under the IOP will
need to be restarted. Tape/Optical devices under the IOP may need to be
varied back on.
To determine the cause of the IOP Reset/Reload, check the Product
Activity Log for additional entries logged with the same System Log ID,
and perform any actions indicated for those errors.
5276
IOP Reset was issued
LIC has detected a problem with the Service Processor IOP and has reset it
but has not initiated reload of the Service Processor.
If the load source is mirrored, some system operations may be able to
continue normally. However, some system service operations have been
suspended and the system should be scheduled for power down as soon as
possible.
Perform a system IPL. If the IPL is successful, then perform LIC-PIP1 to
determine the cause of the problem.
If the system IPL is not successful, perform the action described in the new
SRC.
5310
System LIC program exception occurred
System LIC detected a logical partition configuration data consistency error.
Copy the Product Activity Log data for this error and any related entries
and contact your next level of hardware service support.
B6xx (including A6xx)
Failing Item
AJDG301
FI00130
UG3USR1
UG3USR1
FI00130
AJDG301
FI00310
FI00318
FI00065
FI00130
AJDG301
AJGLD01
AJDG301
FI00021
LPARSUP
273
System Reference Codes

Advertisement

loading