Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 146

Hide thumbs Also See for iSeries Series:

Advertisement

2748, 2757, 2763, 2778, 2782, 5703
Reference Code
Description/Action Perform all actions before exchanging Failing Items
8012
Attached read cache devices exceed capacity supported by IOA
Reduce the number of read caches on the IOA.
8100
I/O processor Licensed Internal Code error
8130
IOA detected recoverable device bus error
An error occurred on SCSI bus 0. No action is required. This reference code
is logged for information only.
8131
IOA detected recoverable device bus error
An error occurred on SCSI bus 1. No action is required. This reference code
is logged for information only.
8132
IOA detected recoverable device bus error
An error occurred on SCSI bus 2. No action is required. This reference code
is logged for information only.
8133
IOA detected recoverable device bus error
An error occurred on SCSI bus 3. No action is required. This reference code
is logged for information only.
8140
IOA detected recoverable device bus error
No action is required. This reference code is logged for information only.
8141
IOA detected recoverable device error
No action is required. This reference code is logged for information only.
8145
A recoverable I/O processor error occurred.
8146
Disk device detected recoverable error
8150
A permanent I/O processor failure occurred
8151
I/O processor Licensed Internal Code error
8155 to 8156
A permanent I/O processor failure occurred
8157
I/O adapter card error
Display the Service Action Log entry for this SRC. If the Failing Item
indicates I/O adapter, then replace the I/O adapter. If the Failing Item
indicates SVCDOCS, then do NOT replace the I/O adapter. This is a
recoverable error. Perform the following for the I/O processor that the I/O
adapter is attached to:
1. If the I/O Processor is not operable and disk units are attached, use
Hardware Service Manager to re-IPL the IOP. Other resources attached to
the IOP may then need to be Varied On.
2. If disk units are not attached, perform the VRYCFG RESET(*YES)
command to reset the IOP and Vary On attached resources.
8200
I/O processor Licensed Internal Code error
9000
I/O processor card detected device error
142
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)
Failing Item
SVCDOCS
AJDGP01
IOP
STORIOA
FI01105
STORIOA
ANYBRDG
AJDGP01
STORIOA
AJDGP01
STORIOA
SVCDOCS
AJDGP01
IOP
FI01105
STORIOA

Advertisement

loading