TDK-Lambda GENESYS Series User Manual page 24

Lan interface
Hide thumbs Also See for GENESYS Series:
Table of Contents

Advertisement

Settings: These fields show, and allow you to change, the selected power supply's
output voltage and current setpoints and if the output is set on or off.
The settings cannot be changed until you have logged-in as 'admin'.
(see section 6.4 above for log-in)
1. Login as 'admin'
2.
Click to show check
The "Refresh" button is used if the "Check to Modify" box is checked.
In this case, clicking the button will read back and show the power supply settings.
This is useful if the supply is in local mode (front panel control).
If the "Check to Modify" box is not checked, refreshing is automatic.
Faults: For the selected supply, these boxes show any faults which may be active in
the supply. These are the first eight bits in the Questionable Condition register, which is
read by the STAT:QUES:COND? query and described in section 11.8.15.
In this picture, the Foldback fault protection has tripped. The power supply output will
be set off.
See Genesys™ Technical Manual for a description of the faults and how to recover
from them.
8303460000 Rev A
3. Enter desired voltage or current setpoints
and if the output should be on or off
4. Click "Apply". See the supply's output change
23