3. Installation
3.2

Setting the node address and the field bus baud rate

Festo P.BE-VIDN-03-8A-GB 0003NH
The following switches can be found under the cover of the
field bus connection module:
DIL switches for setting the field bus baud rate
address selector switches for selecting the node address
Open the cover as follows:
S
If necessary, disconnect the field bus and operating volt-
age cables.
S
Unscrew and remove both Philips screws in the cover.
S
Carefully lift up the cover and remove it.
Close the cover as follows:
S
Carefully place the cover in position.
S
Carefully tighten the Philips screws in the cover.
1
1
Address selector switch (node address)
2
DIL switch for baud rate
Fig. 3/2: Setting elements under the cover of the housing