c. Select the port number of the port used to make this ISL connection.
d. Ensure that the Operational State field displays Online and the Reason field displays N/A
or is blank. If an ISL segmentation or other problem is indicated, refer to the HP
StorageWorks Edge Switch 2/32 service manual to isolate the problem. If no problems are
indicated, installation tasks are complete.
7.
At the HAFM appliance's Product View page, double-click the switch icon. The Hardware View
page for the selected switch is displayed.
8.
Double-click the port connector used to make this ISL connection to open the Port Properties
dialog box
Figure 38

Port Properties dialog box

9.
Ensure that the Link Incident field displays None and the Reason field is blank. If an ISL
segmentation or other problem is indicated, refer to the HP StorageWorks Edge Switch 2/32
service manual to isolate the problem. If no problems are indicated, installation tasks are
complete.
NOTE:
If the Open Trunking feature is installed, an additional field (Congested Threshold %) is
displayed in the Port Properties dialog box. This field displays the active congested threshold
percentage currently configured in the Configure Open Trunking dialog box.
66
Installing and configuring the Edge Switch 2/32
(Figure
38).