Power Requirements; Operating Tolerances - HP StorageWorks Edge Switch 2/32 Installation Manual

Hide thumbs Also See for StorageWorks Edge Switch 2/32:
Table of Contents

Advertisement

Table 7
Environmental specifications (continued)
Specification
Maximum wet-bulb
temperature
Altitude

Power requirements

Table 8
lists Edge Switch 2/32 power requirements.
Table 8

Power requirements

Specification
Input voltage
Input frequency

Operating tolerances

Table 9
lists heating and cooling specifications, shock and vibration tolerance, acoustical noise,
and inclination.
Table 9

Operating tolerances

Specification
Heat dissipation
Cooling airflow
clearances
Shock and vibration
tolerance
Acoustical noise
Inclination
106
Technical specifications
Shipping
Storage
84° F (29° C)
84°F (29°C)
40,000 ft
40,000 ft
(12,192 m)
(12,192 m)
Value
100 to 240 VAC
47 to 63 Hz
Value
836 BTU/hr (32 ports)
Right and left sides: No clearance required
Front and rear: 7.6 cm (3.0 in)
Top and bottom: No clearance required
60 Gs for 10 milliseconds without nonrecoverable errors
6.6 Bels
10° maximum
Operating
81°F (27°C)
10,000 ft
(3,048 m)

Advertisement

Table of Contents
loading

Table of Contents