TECHNICAL SPECIFICATIONS

Technology
Detection mode
Max. detection range
Opening angle
Angular resolution
Typ. min. object size
Door wing safety
Pinch zone safety
Testbody
Emission characteristics
IR LASER
Supply voltage
Power consumption
Response time
Output
Max. switching voltage
Max. switching current
LED-signals
Dimensions
Material - Colour
Tilt angles
Protection degree
Temperature range
Humidity
Vibrations
Min. door wing speed
Norm conformity
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA-SENSORS.COM
BEA hereby declares that the LZR
of the directives 2006/95/EC, 2011/65/EU, 2004/108/EC and 2006/42/EC.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13089611
Angleur, June 2015
The complete declaration of conformity is available on our website: www.bea-pedestrian.be
Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)
LASER scanner, time-of-flight measurement
Presence
4 m (diagonal) with reflectivity of 2% (i.e. : at W = 1.5m -> max. H = 3.7 m)
Door wing safety: 90° / Pinch zone safety: 16°
Door wing safety: 1.3°/ Pinch zone safety: 0.2°
10 cm @ 4m (in proportion to object distance)
2 cm @ 4m (in proportion to object distance)
700 mm × 300 mm × 200 mm (testbody A according to EN 16005 & DIN 18650)
Wavelength 905 nm; max. output pulse power 25 W; Class 1
12 - 24 V DC ± 15 %
≤ 2 W
Door wing safety: max. 50 ms / Pinch zone safety: max. 90 ms
2 electronic relays (galvanic isolation - polarity free)
42V AC/DC
100 mA
1 bi-coloured LED: detection/output status
142 mm (L) × 85 mm (D) × 23 mm (H) ( mounting bracket + 7 mm )
PC/ASA - Black - Aluminium - White
+2° à +10° (without mounting bracket)
IP54
-30°C to +60°C if powered
0-95 % non-condensing
< 2 G
2°/sec
2006/95/EC: LVD; 2011/65/EU: RoHS 2; 2004/108/EC: EMC; 2006/42/EC: MD;
EN 12978: 2009; EN ISO 13849-1: 2008 Pl "d"/ CAT2; EN 60529: 2001;
IEC 60825-1: 2014; EN 60950-1: 2013;
EN 61000-6-2: 2005; EN 61000-6-3: 2011; EN 62061: 2012 SIL 2;
DIN 18650-1: 2010 Chapter 5.7.4 (testbody A);
EN 16005:2012 Chapter 4.6.8 (testbody A)
-FLATSCAN SW is in conformity with the basic requirements and the other relevant provisions
®