TECHNICAL SPECIFICATIONS

Supply voltage*:
12 V - 30 V DC +/-10%
Power consumption:
< 2.5 W
Mounting height:
2 m to 3.5 m
Temperature range:
-25°C to +55°C; 0-95% relative humidity, non condensing
Degree of protection:
IP54 (IEC/EN 60529)
Noise:
< 70 dB
Detection mode:
Technology:
Output*:
Safety Standards:
BEA SA | LIEGE Science Park | Allée des Noisetiers, 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | info-eu@beasensors.com | www.beasensors.com
BEA hereby declares that this product is in conformity with the European directives:
2014/53/EU (RED), 2006/42/EC (Machinery),2011/65/EU (ROHS).
EC-type examination certificate from TÜV NORD CERT : 44 205 13089612.
The complete declaration of conformity is available on our website.
This product should be disposed of separately from unsorted municipal waste.
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V DC/ 30 V AC
- in switching mode: NO/NC
- in frequency mode: pulsed signal
(f= 100 Hz +/- 10%)
- In inverted frequency mode: pulsed signal
in detection (f = 2.5 Hz)
Galvanically isolated current source
No detection: current source ON
Open circuit voltage: 6.5 V
Output voltage available at 10 mA: 3 V min.
Typical load: up to 3 optocouplers in series
Detection: current source OFF
Open-circuit residual voltage: < 500 mV
EN ISO 13849-1 PL «d» CAT. 2
EN 16005 (emergency exits)
DIN 18650-1 (emergency exits)
AutSchR
(only applicable for radar output in
frequency mode and current source output)
Presence
Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 5 cm x 5 cm (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
2
Input:
Pulse polarity: positive or negative (adjustable)
Impedance:
- Positive pulse: 2 K to ground
- Negative pulse: 470 R to + sensor power supply
Pulse voltage: 6 V to 30 V
Pulse duration: 4 µs to 500 µs
Duty cycle: max. 50%
Output:
Pulse polarity: negative
Level:
- Standby: Pulse from V to ground
- Detection: V Supply
Topology: op-collector with 4.7 K to 3.3 V
Max. sink current: 25 mA with external 1 K to 24 V
EN ISO 13849-1 PL «c» CAT. 2
(under the condition that the door control system
monitors the sensor at least once per door cycle)
EN 16005 (protective devices)
DIN 18650-1 (protective devices)
EN 12978
Specifications are subject to changes without prior notice.
All values measured in specific conditions and with a temperature of 25°C.
* External electrical sources must be within specified voltages, max 15W and ensure
double insulation from primary voltages.

Advertisement