Fresh air intake

In a well-insulated house, the air used up by the burning process has to
be replaced. This particularly applies to houses with mechanical ven-
tilation. There are different ways of making sure that an air exchange
takes place. The most important thing is to ensure that there is a sup-
ply of air to the room where the wood stove is located. The external
wall vent must be located as close to the wood stove as possible, and
you must be able to close it when you are not using the wood stove.
Beware that the valve in the outer wall cannot be covered by accident!
National and local building regulations must be followed with regard
to the connection of fresh-air intake.

Closed combustion system

You should use the closed combustion system for the wood-burning
stove if you live in a newly-built, airtight home. Outside air for com-
bustion is connected through a ventilation pipe via the wall or floor.
It must be possible to shut off the ventilation pipe with a valve, when
the stove is not in use.
• Minimum Ø100 mm ventilation pipe, maximum length: 6 m with
a maximum of one bend
The connecting piece for external combustion air is to be found in the
packaging.
If the external combustion air is connected at the rear, the dis-
mounted plate must be mounted on the hole for external air in the
bottom of the stove.
NOTE: if the stove has a fresh air connexion or closed combustion,
the ventilation pipe must be open, when the stove is in use!
Scan 1010
NAVN:
MATERIALE:
DIMENSION:
Mounting of external air supply
C:\Working Folder\Designs\Scan 1010\91010036.idw
STI:
Dismount the cover plate behind or below the casette
External combustion
air on the bottom of
the cassette
A S S E M B LY
Frisklfuft bund
EMNE:
Scan 1010
NAVN:
EMNE:
MATERIALE:
DIMENSION:
C:\Working Folder\Designs\Scan 1010\91010037.idw
STI:
External air
supply on the
rear of the cas-
sette
Scan 1010
NAVN:
EMNE:
MATERIALE:
Mounting of external air supply
on the bottom of the cassette.
Mount the Ø100 sleeve.
Mounting of external air supply
on the rear of the cassette.
Dismount the cover plate at the rear and mount it in the bottom.
N/A
VÆGT:
N/A
AREAL:
Mount the Ø100 sleeve.
dækplade friskluft
N/A
VÆGT:
N/A
AREAL:
friskstuds bag
N/A
VÆGT:
Ø100 sleeve
91010036
TG.NR:
jm
18-08-16
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
91010037
TG.NR:
jm
18-08-16
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
Ø100 sleeve
91010038
TG.NR:
jm
18-08-16
DATO:
SIGN:
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents