Advertisement

A S S E M B LY - A N D I N S T R U C T I O N S M A N U A L
UK
Scan 1010 Series
Congratulations on your new Scan wood-burning stove
You have purchased a product by one of Europe's leading manufacturer's of wood-burning stoves, and we are sure that you will have years of pleasure
with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Please read this Assembly- and instructions manual before you start to assemble your stove.
Product registration number
Please indicate the product registration number at any enquiry
S C A N A / S - D K - 5 4 9 2 V I S S E N B J E R G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1010 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SCAN 1010 Series

  • Page 1 A S S E M B LY - A N D I N S T R U C T I O N S M A N U A L Scan 1010 Series Congratulations on your new Scan wood-burning stove You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of pleasure with your purchase.
  • Page 2: Table Of Contents

    C O N T E N T S Table of contents Technical data ......................3 Installation Safety Technical data and dimensions Dimension sketch Type plate Product registration number Additional accessories Loose parts Assembly ........................8 Remove packaging Positioning your wood-burning stove Load bearing foundation Distances to combustible floor.
  • Page 3: Technical Data

    Any changes made to the product by the dealer, installer or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
  • Page 4 Surface treatment: ................Senotherm The Scan 1010 was build in compliance with the homologized product Max. wood length: ..................50 cm type specified in the Assembly- and Instructions Manual provided with the product.
  • Page 5: Dimension Sketch

    T E C H N I C A L D ATA Dimension sketch Scan 1010 324,5 D 143 D 324,5 B A Centre rear outlet B Top outlet C Height to the beginning of the connecting piece at top outlet...
  • Page 6 T E C H N I C A L D ATA Dimension sketch Scan 1010 143 D 324,5 D 324,5 B A Centre rear outlet B Top outlet C Height to the beginning of the connecting piece at top outlet...
  • Page 7 SIGN: shield. Cover for DIMENSION: AREAL: Krog Iversen & Co A/S Large module fresh air inlet - is not to be DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1010\91010034.idw STI: used under the stove! Scan 1010 Friskluft skjuler NAVN: EMNE: TG.NR: 91010033 DATO:...
  • Page 8: Type Plate

    T E C H N I C A L D ATA / A S S E M B LY Additional accessories Type plates All Scan wood-burning stoves are fitted with a type plate, that speci- • Large/small module fies the approval standards and the distance to flammable materials.
  • Page 9 Load bearing underlay All of the products in our portfolio are classified as light-duty firepla- Scan 1010 ces; in most cases, there is no need to reinforce the floor, so that you can typically use the normal floor.
  • Page 10: Assembly

    Carrying capacity assembly of fresh air box Scan 1010 NAVN: EMNE: TG.NR: 12-04-2016 DATO: MATERIALE: VÆGT: M3 NR.: DIM.: AREAL: Scan A/S DK-5492 Vissenbjerg C:\Working Folder\Designs\Scan 1010\21010909.iam STI:...
  • Page 11: Distance To Flammable Materials, Shown With Insulated Flue Pipe

    A S S E M B LY Distance to flammable materials, shown with un-insulated flue pipe* Scan 1010 45° Corner installation Parallel rear wall installation Distance to flammable materials, shown with insulated flue pipe* The distances presuppose the use of an insulated flue pipe with min. 30 insulation all the way to the stove.
  • Page 12: Distance To Firewall

    The indicated distances are valid for insulated as well as un-insulated smoke pipes. Scan 1010 1000 1000 Flammable material Firewall Brandmur og isoleret røgrør - Scan 64 uden sideglas Scan 64 TG.NR: NAVN: EMNE: 29-08-12 * All national and local requirements concerning safety distances for wood burning stoves must be respected.
  • Page 13: Mounting With Plinth

    DIM.: AREAL: Scan A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1010\91010019.idw STI: A ( 0,40 : 1 ) It is important to adjust the plinths before mounting the modules. First mount the module with fresh air inlet on the plinth and then the stove. Place the magnets on the next modules before mounting them.
  • Page 14: Mounting Of The Wall Bracket

    Use only recommended fuels. Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe. 1000 Scan A/S DK 5492 Vissenbjerg 08-2017 Please note First dismount the heat shield at the rear. The heat shield is not used on the wall model.
  • Page 15 It must not rest on the wood-burning stove. There must be a distance of at least 6 mm between the first section and the flange on the flue collar. Please consult a specialist. Scan A/S disclaims all liability for the installation of wall-hung wood-burning stoves.
  • Page 16 4) Mount the module (A) on the wall fitting. Place the stove (B). Put on the indicator plate (C). indikatorplade Scan 1010 NAVN: EMNE: MATERIALE: M3 NR.: DIM.: C:\Working Folder\Designs\Scan 1010\91010045.i STI: justerskive Scan 1010 NAVN: EMNE: indikatorpla Scan 1010 NAVN:...
  • Page 17: Existing Chimney And Pre-Fabricated Element Chimney

    The chimney must be labelled T400 and G for soot testing. Connection with 90° elbow pipe If you intend to use an elbow pipe with the Scan 1010 we recommend the use of a curved elbow pipe to improve the draft.
  • Page 18 Nederste røgvenderplade Scan 1001 NAVN: EMNE: MATERIALE: VÆGT: DIMENSION: AREAL: C:\Working Folder\Designs\Scan 1001\91001041.idw STI: Mount the right burn chamber plate. Place the log guard against the front of the insert. Nederste røgvenderplade Scan 1001 9100 NAVN: EMNE: TG.NR:...
  • Page 19: Fresh Air Intake

    SIGN: MATERIALE: VÆGT: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© Mounting of external air supply C:\Working Folder\Designs\Scan 1010\91010036.idw STI: Dismount the cover plate behind or below the casette Mount the Ø100 sleeve. dækplade friskluft Scan 1010 91010037 NAVN: EMNE: TG.NR:...
  • Page 20: Cb Technique

    I N S T R U C T I O N S F O R H E AT I N G CB-technique (Clean Burning) Secondary air The wood-burning stove is equipped with CB technology. In order Secondary air is pre-heated and fed indirectly to the fire. At the to ensure an optimal combustion of released gases under the inci- same time, the secondary airflow cleans the glass pane to avoid soot neration process, air will pass through a specially developed canal...
  • Page 21: Lighting

    Lighting We recommend the use of fire starters, or similar products, which are available from your Scan dealer. Using fire starters helps to light the wood quicker, and keeps the burning process clean. Never use liquid lighting fuels! "Top down"...
  • Page 22: Handling Fuel

    I N S T R U C T I O N S F O R H E AT I N G Using your stove in the spring or autumn Handling fuels In the transition period (spring/autumn), where there is less need for heating, we recommend to make a single „top down“...
  • Page 23: Maintenance

    Clean your wood-burning stove by dusting with a dry, lint-free cloth. If the topcoat is damaged, you can purchase a repair spray from your authorised Scan dealer. As slight differences in colour are possible, Baffle plates and combustion chamber liningg spray a larger area to achieve a natural transition for best results.
  • Page 24: Troubleshooting

    • Not enough wood • Inferior wood quality with low fuel value • This warranty is only valid in the country to which this Scan pro- duct was originally supplied. • Baffle plates are not fitted correctly...
  • Page 25: Defra

    Clean Air Act require- ments” The Scan 1010 has been recommended as suitable for use in smoke control areas when burning wood logs with a modification to thery air valve so that it will not close beyond the 40% open position.
  • Page 27 M A I N TEN A N C E...
  • Page 28 Version: Scan A/S - DK-5492 Vissenbjerg GB 91010 500 14.02.2018...

Table of Contents