Page 1
Test in compliance with EN 13240 Make a note of your stove’s product registration number here so that you Version GB 13.02.08 - 1 have it available if you need to contact The EC declaration of conformity is available from www.scan.dk...
TA B L E O F C O N T E N T S Table of contents Installation ...................... 3 Installation Approva Technical data and dimensions Assembly ......................4 Unpacking Service package Load bearing underlay Floor plate Ajusting screws Compartment under combustion chamber Type plate Product registration number Rotating plinth...
To ensure best-possible functionality and safety for your installa- Recommended vacuum in flue collar: 16 Pa tion, we advise you to call a professional fitter. Our Scan Dealer will be able to recommend a qualified fitter in your area. For information Combustion air requirement: 21 Nm3/h on Scan Dealers, please go to www.scan.dk.
If you have chosen the Scan 53 wall-hung model, the floor plate must extend right back to the hanging wall. Adjusting screws Scan 53 is equipped with 4 adjusting screws at the base of the wood- burning stove. You can use the screws to level the stove.
(see front). Product registration number Accessories * Centre rear outlet • Shaped floor plate in steel or glass (N/A for the Scan 53 wall- ** Height to the beginning hung model) of the flue pipe at top outlet •...
The chimney must be labelled T400 and G for soot testing. Connection with 90° elbow pipe If you intend to use an elbow pipe with the Scan 53 and Scan 53 wall-hung model, we recommend the use of a curved elbow pipe to improve the draft.
A S S E M B LY Flue collar top outlet Preparing the stove for rear outlet Your wood-burning stove has been prepared for a top outlet by the To connect the flue pipe, remove the cover plate as follows: manufacturer.
Fitting the fresh-air connection piece In a well-insulated house, the air used up by the burning process has The Scan 53 og Scan 53 wall-hung model can be connected using a to be replaced. This particularly applies to houses with mechanical fresh-air connection piece.
I N S T R U C T I O N F O R U S E CB Technology (Clean Burning) Smoke deflector plates Your wood-burning stove is fitted with CB technology. To ensure The smoke deflector plates are located in the upper part of the com- optimum burning of the gases released by the burning process, air bustion chamber.
No matter how good your chimney is, it will not perform well if you are available from your Scan dealer. Using fire starters helps to light do not use it correctly. On the other hand a poor chimney, may give the wood quicker, and keeps the burning process clean.
You can easily remove this build up by cleaning Painted, pressure impregnated, or glued wood, driftwood from the with a dry cloth and glass cleaner. Your authorised Scan dealer stocks sea. Never burn chipboard, plastics, or chemically treated paper.
• In case of repairs that do not comply with our instructions or The surface of the stove is turning grey instructions by an authorised Scan dealer. • In case of any manipulation of the original state of this Scan • Overheating (see instructions for heating) product or its accessories.
Need help?
Do you have a question about the Scan 53 and is the answer not in the manual?
Questions and answers