Fresh Air Intake; Closed Combustion System - SCAN 65-1 Assembly And Instruction Manual

Table of Contents

Advertisement

18
Hook the natural stone sides onto the stove.
Montage af fedtstenssider
EMNE:
Folder\Designs\Scan 64\90064032.idw
Montage af fedtstenssider
64
EMNE:
ng Folder\Designs\Scan 64\90064032.idw
N/A
VÆGT:
N/A
AREAL:
N/A
VÆGT:
N/A
AREAL:
A S S E M B LY

Fresh air intake

In a well-insulated house the air used for the combustion process
has to be replaced. This particularly applies to houses with mecha-
nical ventilation. There are different ways of making sure that air is
exchanged. The most important thing is to ensure that there is a sup-
ply of air to the room where the wood stove is located. The external
wall vent must be located as close to the wood stove as possible, and
you must be able to close it when you are not using the stove.
National and local building regulations must be followed with regard
to connection of a fresh air intake.

Closed combustion system

You should use the closed combustion system for the wood-burning
stove if you live in a newly-built, airtight home. External combustion
air is connected through a ventilation pipe via the wall or floor.
It must be possible to shut off the ventilation pipe with a valve, when
the stove is not in use. Minimum Ø100 mm ventilation pipe, maxi-
mum length: 6 meters with a maximum of one bend.
If you want external combustion air via a wall, remove the cover plate
at the rear of the stove with a pair of cutting pliers. See the procedure
in this manual.
If the external combustion air is connected at the rear, the dis-
mounted plate must be mounted on the hole for external air in the
bottom of the stove.
NOTE:
if the stove has a fresh air connection or closed combustion,
the ventilation pipe must be open, when the stove is in use.
90064032
TG.NR:
29-08-12
BC
DATO:
SIGN:
Krog Iversen & Co A/S
Remove the cover plate at the back of the stove or the cover plate at
the bottom of the wood compartment store, as shown on page 15.
DK-5492 Vissenbjerg©
90064032
TG.NR:
Connect outside air to the connection piece underneath the com-
bustion chamber.
29-08-12
BC
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
19
External
combustion
air via wall
External combustion
air via floor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

65-265-665-765-865-965-10 ... Show all

Table of Contents