Page 1
To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove. ASSEMBLY AND INSTRUCTION MANUAL SCAN 68...
Page 2
SCAN 68-SERIEN Scan 68-1 Scan 68-2 Scan 68-3 Scan 68-4 Scan 68-5 Scan 68-6 Wall hung model Wall hung model Pedestal Pedestal Portal Portal Without side windows Without side windows Without side windows Without side windows Without side windows Without side windows...
Technical data and dimensions ..........4 Product registration number ...........12 ¬ ¬ ASSEMBLY Additional accessories ...............12 Wall mounting kit for Scan 68 with high top ......24 Loose parts..................12 Heat-storage stone ..............25 Disposal of packaging ..............12 Height adjustment of stove ............26 Removal of packaging ..............13 Connecting piece ................26...
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
250*** DIMENSION SCAN 68-1, 68-2, 68-7 AND 68-8 (WALL HUNG MODEL) Centre rear outlet Height to the beginning of the connecting piece at top outlet Centre of fresh air intake All measurements are in millimeters Scan 68 Målskitse wall NAVN:...
Page 6
250*** DIMENSION SKETCH SCAN 68-5, 68-6, 68-11 AND 68-12 (PORTAL) Scan 68 Målskitse Portal NAVN: EMNE: MATERIALE: VÆGT: DIMENSION: AREAL: Centre rear outlet C:\Working Folder\Designs\Scan 68\90068001.idw STI: Height to the beginning of the connecting piece at top outlet Centre of fresh air intake...
Page 7
250*** DIMENSION SKETCH SCAN 68-13 AND 68-14LB (LOW BASE) Centre rear outlet Height to the beginning of the connecting piece at top outlet Name: Stove: Centre of fresh air intake Material: All measurements are in millimeters 108,41 kg Articlenumber: Weight: Area: C:\Working Folder\Designs\Scan 68\90068155.idw...
Page 8
DIMENSION SKETCH SCAN 68-13 AND 68-14 HT (HIGH TOP) 250*** Scan 68 NAVN: EMNE: MATERIALE: VÆGT: DIMENSION: AREAL: C:\Working Folder\Designs\Scan 68\90068080.idw STI: Centre rear outlet Height to the beginning of the connecting piece at top outlet Centre of fresh air intake...
Page 9
250*** DIMENSION SKETCH SCAN 68-13 AND 68-14 (SOAPSTONE + LOW BASE) Centre rear outlet Height to the beginning of the connecting piece at top outlet Name: Stove: Centre of fresh air intake Material: All measurements are in millimeters 108,41 kg...
Page 10
DIMENSION SKETCH SCAN 68-15 AND 68-16 HT (SOAPSTONE + HIGH TOP) Scan 68 målskitse fedtsten HT NAVN: EMNE: MATERIALE: VÆGT: DIMENSION: AREAL: C:\Working Folder\Designs\Scan 68\90068137.idw STI: Centre rear outlet Height to the beginning of the connecting piece at top outlet...
TYPE PLATE All Scan wood-burning stoves are fitted with a type plate that specifies the approval standards and the distance to flam- mable materials. The type plate is located at the rear of the stove. Typeplates Scan 68-1 and 68-2...
PRODUCT REGISTRATION NUMBER All Scan wood-burning stoves are provided with a product registration number. You will always need to quote this number when contacting your dealer or Scan A/S. The product registration number is located at the rear of the stove.
Check that the stove is not damaged before starting to install it. Please remove protection Remove the two screws in the wood compartment and lift the stove off the pallet. Scan 58 Scan 58-7 - 10 afmontage ovn på palle NAVN: EMNE: TG.NR: 90358170...
MOUNTING OF THE DOOR ASSEMBLY Dismount the door. Remove the four screws under the stove before placing the door assembly. Carefully push the door First mount the four Dismount the door. assembly in from behind. screws at the top. The 4 outer screws at the Remount the door.
There must be a distance of at least 6 mm between the first section and the flange on the flue collar. Please consult a specialist. Scan A/S disclaims all liability for the installation of wall-hung wood-burning stoves. Must be removed, also in the...
Page 19
Use the guide blocks to hold the wall fitting while MATERIALE: VÆGT: adjusting it. DIMENSION: AREAL: 169 mm C:\Working Folder\Designs\Scan 68\90068058.idw STI: Use the line or a spirit level. Drill the necessary holes and mount the screws. justeringsskive til vægbeslag justeringsskive til vægbeslag Scan 68...
Page 20
(See instructions in this manual). The two screws under the stove must be removed, before lifting the stove up on the wall fitting. If you want a rear outlet, see page 26 in this manual. mont skruer væghængt Scan 68 NAVN: EMNE: TG.NR: 90068065...
FITTING NATURAL STONE Scan 68-15 and Scan 68-16 are supplied with loose pieces of natural stone that are fitted to the sides of the stove. Natural stone is made from a natural material and consequently its pattern and shape may vary.
If you choose to connect the stove with an elbow pipe or a rear outlet, the stove must be mounted to the wall behind the oven using a special wall mounting kit. This kit can be purchased from your local Scan dealer. For fitting, see instructions in this manual.
If you choose to connect the stove with an elbow pipe or a rear outlet, the stove must be mounted to the wall behind the oven using a special wall mounting kit. This kit can be purchased from your local Scan dealer See instructions in this manual for how to fit the high top.
HEIGHT ADJUSTMENT OF STOVE The Scan 68 has four adjustment screws under the stove. Use the adjustment screws to get the stove to stand straight and level. Tilt the wood-burning stove and adjust the adjustment screws. If you are using a shaped floor plate, you should adjust the stove upwards to allow the plate to be inserted under the front of the stove.
EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chimney sweep, for advice. These experts will also let you know if your chimney needs renovating.
A floor plate can be made of steel or glass, but the stove can also be erected on clinker concrete, natural stone or similar materials. This Scan wood-burning stove has an integrated floor plate at the bottom and can thus be erected directly on flammable material without the need for further protection underneath the stove.
, SHOWN WITH UN-INSULATED FLUE PIPE DISTANCE TO FLAMMABLE MATERIALS, 45° Corner installation Parallel rear wall installation A: 100 mm B: 350 mm A: 400 mm B: 500 mm *100/**350 *100/**350 A: 100 mm *150/*150 *150/*150 B: 350 mm A: 150 mm B: 150 mm DISTANCE TO FLAMMABLE MATERIALS, SHOWN WITH INSULATED FLUE PIPE The distances presuppose the use of an insulated flue pipe with min.
DISTANCE TO FIREWALL 110 mm brick, 50 mm JØTUL Firewall or other material with a corresponding insulation ability. The indicated distances are valid for insulated as well as un-insulated smoke pipes. A: 1000 mm A: 1100 mm B: 1000 mm *1000/**1000 B: 1200 mm *1100/**1200...
INSTRUCTIONS FOR USE CB TECHNOLOGY (CLEAN BURNING) The stove is equipped with CB technology. In order to ensure optimal combustion of gases released during the combus- tion process, air passes through a specially developed system of channels. The heated air is conducted into the combus- tion chamber through the holes in the rear lining of the combustion chamber and at the baffle plates.
National and local building regulations must be followed with regard to connection of a fresh air intake. NOTE: WHEN CONNECTING THE SCAN 68 LOW BASE WITH A FRESH AIR INLET, WE RECOMMEND THAT YOU USE A SHORT, AN- GLED CONNECTION PIECE BECAUSE OF THE LIMITED SPACE IN THE BASE. (FOR EXAMPLE JØTUL PRODUCT NO. 101395-F373).
LIGHTING We recommend the use of fire lighters, or similar products, which are available from your Scan dealer. Using fire lighters helps light the wood more quickly and keeps the combustion process clean. NEVER USE LIQUID LIGHTING FUELS! “TOP DOWN”...
CONTINUOUS FIRING It is important to obtain as high a temperature as possible in the combustion chamber. This results in best possible use of the stove and fuel, as well as achieving clean combustion. In this way you will avoid build-up of soot on the combustion chamber lining and glass pane.
HANDLING FUEL SELECTING WOOD/FUEL You can use any type of wood as fuel. However harder woods, such as beech or ash, are generally better for heating, as they burn more evenly and create less ash. Other woods, such as maple, birch and spruce, are excellent alternatives. PREPARATION The best fuel is obtained where the tree has been felled and the wood sawn and split before May 1st.
Page 37
Make sure the stove is cold before starting maintenance or repair work. CHECKING THE STOVE Scan A/S recommends that you check your stove thoroughly after sweeping/cleaning. Check all visible surfaces for cracks. Check that all joints are tight and that the gaskets are correctly seated. Worn or deformed gaskets should be replaced.
Page 38
Mount skamol plate 4a and 4b. A ( 1 : 5 ) When skamol plates 1-4 are inserted, it should look like this. Mount skamol plate 5a and 5b. Make sure that the two baffles are placed identically. Scan 68 Skamol 1 90068039 NAVN: EMNE: TG.NR:...
Page 39
Clean your wood-burning stove by wiping it down with a dry, lint-free cloth. skamol færdig TG.NR: 90068048 If the paint finish gets damaged, you can purchase repair paint in spray form from your Scan dealer. As slight differenc- 27-04-2015 VÆGT: DATO: SIGN: es in color shade are possible, we recommend you spray a larger area to achieve a natural blend.
Page 40
TROUBLESHOOTING SMOKE ESCAPING ¬ Damp wood ¬ Chimney not drawing properly ¬ Chimney is not properly dimensioned for the stove ¬ Check if the smoke gas pipe/chimney are blocked ¬ Is the chimney the right height for its surroundings? ¬ Vacuum in room ¬...
Page 41
You must quote your stove‘s product registration number when you contact us or your authorized Scan dealer with a warranty claim. The warranty covers all parts which in the opinion of Scan A/S require repair or replacement due to manufacturing or construction error The warranty applies to the original purchaser of the product only, and is not transferable (except on prior sale).
Page 43
Open both, secondary and primar air control to mount the screw. Open both, secondary and primar air control to mount the screw. After mounting the UK screw A ( 0,40 : 1 ) After mounting the UK screw Scan 68 skrue uk mont 90068079 NAVN: EMNE: TG.NR:...
Page 44
Product registration number Quote this number at all enquiries Edition: UK 90068500 SCAN A/S Glasvænget 3-9 DK-5492 Vissenbjerg www.scan.dk 01.01.2018...