Userdefinition Parameter - KEB COMBICONTROL C5 Instruction Manual

Table of Contents

Advertisement

COMBICONTROL
pi.07
axis outdata 3
Displays the value of the third process-output data (16 Bit) of the axes. Set 0 is for the
data of axis 1, set 1 for the axis 2, etc.
pi.08
fieldbus indata
Displays the value of the Fieldbus-input data. Set 0 displays the first word, set 1 displays
the second word, etc.
pi.09
fieldbus outdata
Displays the value of the Fieldbus-output data. Set 0 displays the first word, set 1 displays
the second word, etc.
3.3.5 Userdefinition parameter
ud.00
program operation
The current program operation mode (run/stop) is displayed or adjusted here. Furthermo-
re a reset or reset cold can be executed with this parameter.
ud.01
password
Password input for the corresponding user level. The following values for the password
step are possible:
200
User write protection (operating parameter cannot be changed)
440
User reading/writing
Note: The value for the reading/writing password can be changed with parameter ud.08.
ud.02
features
Display of the actual disconnected special functions (e.g. SoftMotion)
ud.03
IO module
This parameter displays the installed I/O module.
ud.04
fieldbus module
This parameter displays the installed Fieldbus module.
ud.05
error counters rx
This parameter counts the receive errors during the communication with the axes. Set 0
displays the errors of axis 1, set 1 of axis 2 etc.
GB - 22
Address
0507h
Address
0508h
Address
0509h
Address
0800h
Address
0801h
Address
0802h
Address
0803h
Address
0804h
Address
0805h