IBM Power Systems S812LC 8348-21C Installation Manual page 69

Installing the system and ordered parts
Hide thumbs Also See for Power Systems S812LC 8348-21C:
Table of Contents

Advertisement

Cables
Use multimode fiber optic cables with shortwave lasers that adhere to the following specifications:
v OM3 or OM4: Multimode 50/125 micron fiber, 2000 MHz x km bandwidth
v OM2: Multimode 50/125 micron fiber, 500 MHz x km bandwidth
v OM1: Multimode 62.5/125 micron fiber, 200 MHz x km bandwidth
Because core sizes are different, OM1 cables only can be connected to other OM1 cables. For best results,
OM2 cables must not be connected to OM3 or OM4 cables. However, if an OM2 cable is connected to an
OM3 or OM4 cable, the characteristics of the OM2 cable apply to the entire length of the cables. The
following table shows the supported distances for the different fiber optic cable types at different link
speeds.
Table 12. Supported distances for multimode fiber optic cables
Header
Rate
10 Gbps
Operating system or partition requirements
If you are installing a new feature, ensure that you have the software that is required to support the new
feature and that you determine whether there are any prerequisites for this feature and attaching devices.
To check for the prerequisites, see IBM Prerequisite website (www-912.ibm.com/e_dir/eServerPrereq.nsf).
The adapter is supported on the following versions of the operating systems, depending on the system
you are using:
v AIX
– AIX 7.1with the 7100-03 Technology Level and Service Pack 3, or later
– AIX 6.1, Technology Level 9, Service Pack 2, or later
v Linux
– Red Hat Enterprise Linux Version 6.5, or later, with current maintenance updates available from Red
Hat.
– Red Hat Enterprise Linux Version 7, or later, with current maintenance updates available from Red
Hat.
– SUSE Linux Enterprise Server Version 12, or later
– SUSE Linux Enterprise Server 11, Service Pack 3, or later, with current maintenance updates
available from SUSE.
– Ubuntu Server 14.04.3, or later
– For support details, see the Linux Alert website (www14.software.ibm.com/webapp/set2/sas/f/
lopdiags/info/LinuxAlerts.html).
v IBM i
– IBM i is supported only with VIOS
This adapter requires the following drivers:
v AIX: devices.pciex.e4148a1614109304 for SFP+ optical ports and devices.pciex.e4148a1614109404 for
RJ45 ports
v Linux: bnx2x driver
v The latest version of the device driver or iprutils can be downloaded from IBM Service and
Productivity Tools website (http://www14.software.ibm.com/webapp/set2/sas/f/lopdiags/
home.html).
OM1
0.5 meters to 33 meters
(1.64 feet to 108.26 feet)
Cable Type and Distance
OM2
0.5 meters to 82 meters
(1.64 feet to 269.02 feet)
Installing and configuring the system
OM3
0.5 meters to 300 meters
(1.64 feet to 984.25 feet)
53

Advertisement

Table of Contents
loading

Table of Contents