10.
Control Levers
10.1
Master Control Lever
STOP
The positions of the Master Control
lever are described in the instruction
manual.
10.1.1 Removing and Installing
1
– Remove the filter base, b 12.3
: Pull off the rubber buffer (1).
78
1
: Pry the switch shaft (1) out of its
mount (arrow).
: Lift the switch shaft (1) a little and
pull it away.
– Check the switch shaft (1) and
replace it if necessary
Installing
1
2
: Push the switch shaft (1) onto the
pin (2).
1
: Carefully push the switch shaft
(1) over the taper (arrow).
: Push the switch shaft (1) onto the
pin (2) until it snaps into position.
1
2
: Push the rubber grommet (1)
onto the pin (2).
– Install the filter base, b 12.3
– Reassemble all other parts in the
reverse sequence.
– Check operation.
MS 362, MS 362 C