7.7.4
Contact Spring
– Remove the shroud, b 6.4
– Remove the choke rod,
b 10.3.3
2
: Move the switch shaft (1) towards
the tank housing until the contact
spring (2) is free.
1
: Lift the contact spring (1) over the
lug (arrow) and pull it out.
– Check the contact spring and
replace it if necessary, b 7.7.4
MS 362, MS 362 C
Installing
1
: Push the contact spring (1) onto
the pin (arrows) as far as stop.
Make sure the lug (arrow) locks the
contact spring in position.
: Lift the contact spring (1) and
push it over the switch shaft.
1
: Check operation
– short circuit wire's connector
must touch the contact spring
(arrow) in position "
– Reassemble all other parts in the
reverse sequence.
1
0
".
57