STIH) Technical Information 11.2013 New STIHL MS 362 C-M Chain Saw – Series 1140 Contents 1. Technical Description 2. Shroud 3. HD2 Air Filter 4. Chain Sprocket Cover with Captive Nuts 5. Specifications 6. Repairs 7. Serial Number 8. Repair Times englisch / English TI_11_2013_30_01_01.fm...
– Memory function – Master Control Lever™ with a stop switch function The new STIHL MS 362 C-M is also available in the following versions: STOP or † – Master Control Lever™ must be ® – MS 362 C-MQ with STIHL Quickstop Plus pushed in direction of STOP or †...
Technical Information 11.2013 Page 3 1.1.2 Setting the Master Control Lever™ HD2 Air Filter To move the Master Control Lever™ from the run position F to start }, press down the trigger lockout and squeeze the throttle trigger at the same time and hold them in that position –...
Cleaning the Air Filter Chain Sprocket Cover with Captive Nuts Wash the filter in STIHL special cleaner (special accessory) or clean, non-flammable solution (e.g. warm soapy water) – rinse the filter from the inside outwards under a jet of water – do not use a pressure washer.
Installing the Control Unit Troubleshooting Place the control unit in the crankcase. The STIHL MDG 1 engine analyzer can be used to test the ignition module, control unit (STIHL M-Tronic™) and connected electrical components quickly and reliably. To do this, follow the steps in the diagnostics software after connecting the analyzer.
Page 7
Technical Information 11.2013 Page 7 Push the connector housing (2) onto control Wiring Harness unit's contacts (4) until it clicks into position. 6.3.1 Removing the Wiring Harness Tighten the screw (1) to 4.0 lbf in (0.5 Nm). Pull the connector housing off the control unit – see b 6.2.1 Remove the air filter and baffle.
Page 8
Page 8 Technical Information 11.2013 Join the connector (3) and fit it in the connector housing (4). Push the red wire (9) over the yellow wire (8) into the guide (arrow). Take out the screw (5). Remove protective cap (6) from diagnostic socket.
Page 9
Technical Information 11.2013 Page 9 Installation at fanwheel side Connect yellow ground wire terminal (1) to the filter base – crimped side must face down. Connect black short circuit wire terminal (2) to the switch shaft – crimped side must face up. Engage the terminals in their seats (arrows).
Page 10 Technical Information 11.2013 Switch Unit 6.4.2 Installing the Switch Unit 6.4.1 Removing the Switch Unit Remove the shroud, air filter and baffle. Remove the filter housing. Versions with carburetor heating Take out the screws (1) and remove the heating Fit the switch unit (6) and tighten down the element (2).