Controller Comparisons - Trane Tracer Uc

Programmable bacnet controller for variable-air-volume (vav) units
Table of Contents

Advertisement

Table 1.
UC400 Features (continued)
Feature
Static Pressure Optimization:
Ventilation Optimization:
CO
-based Demand Control
2
Ventilation:
Ventilation Flexibility:
Temperature Statistics:
UC400 Controller Compatibility:

Controller Comparisons

Table 2
Table 2.
Tracer UC400 VAV
Supports BACnet.
Local CO
sensor input is available.
2
Single star (*) initiates cool minimum
(a)
airflow override.
Double star (**) initiates cool maximum
(b)
airflow override.
Does not support VariTrac central control
panel (CCP2 and CCP3).
Supports ventilation flow control.
Supports flow tracking control.
Supports enhanced ventilation control sequences.
Supports auto-commissioning sequence.
Does not support zone sensor air balance sequence.
(a) By simply turning the thumbwheel to *, or increasing the setpoint to maximum on display sensors (end of range in one direction), the controller drives
the air valve to the minimum flow setpoint.
(b) Turning the thumbwheel to the **, or decreasing the setpoint to minimum on display sensors (end of range in the other direction), the controller
drives the air valve to the maximum flow setpoint.
VAV-SVX07B-EN
Description
As a part of the standard application, VAS calculates the duct static pressure setpoint based on the VAV unit with a damper in the
maximum flow position.
As a part of the standard application, the VAV system has the ability to calculate the ventilation setpoint for the air handler unit. In
addition, the UC400 controllers have a ventilation ratio limit feature that automatically increases airflow to maintain the required
ventilation while operating within system limits for outside air percent concentrations in the supply air stream.
As a part of the standard application, the VAV system has the ability to calculate the ventilation setpoint for the air handler unit based
on the CO
concentration in one or more spaces.
2
Ventilation can be managed in the following ways:
• Fixed occupancy ventilation setpoint
• Scheduled (calculated) ventilation setpoint
• Occupancy sensor to switch between normal and reduced ventilation
• CO
sensor for demand-controlled ventilation
2
As a part of the standard application, both the VAS and Area applications calculate the minimum space temperature (and source),
maximum space temperature (and source), and the average space temperature.
The UC400 controller integrates with other BACnet systems and devices using BACnet MS/TP. The UC400 controller provides standard
BACnet objects (data points) that can be read by and/or written to by other systems.
shows the comparison of the UC400 controller to the VV550/551 and the VAV 4.2.
Comparison of the UC400 to VV550/551
Tracer VV550/VV551
Supports LonTalk.
No local CO
sensor input. Uses only a communicated
2
value.
Single star (*) initiates cool minimum
airflow override.
Double star (**) initiates cool maximum
airflow override.
Does not support VariTrac central control
panel (CCP2 and CCP3).
Supports ventilation flow control.
Supports flow tracking control.
Supports enhanced ventilation control sequences.
Supports auto-commissioning sequence.
Supports zone sensor air balance
sequence.
(a)
(b)
VAV 4.2
Supports Trane proprietary Comm4 or Comm3.
Local CO
sensor input is available.
2
Single star (*) initiates maximum flow override after
pressing the ON button. Override is held until the
thumbwheel is adjusted.
Double star (**) initiates unoccupied override after
pressing the ON button. Override is held until the
thumbwheel is adjusted.
Does support VariTrac CCP2 and CCP3.
Does not support ventilation flow control.
Does not support flow tracking control.
Does not support enhanced ventilation control
sequences.
Does not support auto-commissioning sequence.
Does not support zone sensor air balance sequence.