DR 15 manual tare specification

Data recorder DR 15 is used for an external specification of a tare weight.
Procedure
● Enter the tare weight
● Transfer the data record to the scale
● Enable the tare weight using command 1013
Table 8-10
Assignment of data record 15
Variable
Note
Data record
Contains no.
number
of data record
Length
Data record
length infor‐
mation
Application
Information
about which
application
the DR be‐
longs to
Version iden‐
Information
tifier
on the cur‐
rent data re‐
cord version
Specification
Tare specifi‐
of tare
cation memo‐
weight
ry (manual
(Page 84)
tare value)
Reserve
Reserve
SIWAREX WP321
Operating Instructions, 08/2019, A5E33715669A-AD
Type
L
UINT
2
UINT
2
UINT
2
UINT
2
REAL
4
REAL
4
8.13 DR 15 manual tare specification
Decimal code
From DR
4
30
5
30
9
31
10
31
12
30
15
32
-
8
-
11
-
Rw
Default
r
15
r
16
r
201
r
1
rw
0
rw
0