Siemens SIWAREX WP321 Operating Instructions Manual page 51

Electronic weighing system
Hide thumbs Also See for SIWAREX WP321:
Table of Contents

Advertisement

Requirement:
The scale is empty.
Procedure
● Enter the marked and described calibration parameters.
The defined weight unit applies to all weight specifications. You can specify a string with up to 4 digits as the weight
unit, e.g.: t, kg, lbs.
Exceeding the maximum weight (= maximum material to be weighed) is indicated in DS30, status 1-2, at parameter
"Max 9e". If the maximum weight is exceeded, this bit is set to TRUE.
The resolution d is used for the weight display in the SIWATOOL program. You can set the resolution d in accordance
with EN 45501 (0.0001 to 50).
If the scale is not empty during automatic calibration, but the material weight on the scale is known (e.g. after
conversion to SIWAREX WP321), the known material weight can be specified as calibration weight 0. This means the
material weight is taken into account during automatic calibration.
NOTE: If the specified material weight is incorrect (old electronic weighing system was not calibrated correctly, for
example), the weighing result of SIWAREX WP321 will be distorted or incorrect!
Figure 7-15
SIWATOOL: Calibration parameters for automatic calibration (without calibration weight)
Send calibration parameters
● Send the calibration parameters set on your PC to SIWAREX.
● Select "Service mode on" in the Service menu. The calibration parameter (DR3) can only be
sent and the calibration commands executed with service mode switched on.
⇒ After switching on service mode, the following red wrench icon is displayed in the SIWATOOL
next to the weight value.
SIWAREX WP321
Operating Instructions, 08/2019, A5E33715669A-AD
7.4 Fast commissioning (Quick Start) with SIWATOOL
Commissioning
51