Variable
Application [APPL_ID]
Version identifier [DR_VER‐
SION]
Refresh counter
[REFRESH_COUNTER]
Device status
[MODULE_ERROR_IN‐
FORMATION]
Load cell input 1: Status
[LOAD_CELL_INPUT_1_DI‐
AGNOSTIC_INFORMA‐
TION]
Load cell input 1: filtered dig‐
it value
[LOAD_CELL_IN‐
PUT_1_DIGITS_FILTERED]
Load cell input 1: Load (%)
[LOAD_CELL_IN‐
PUT_1_PERCENT‐
AGE_LOAD]
Load cell input 1: Signal volt‐
age SIG (mV)
[LOAD_CELL_IN‐
PUT_1_LOAD_CELL_SIG‐
NAL]
Load cell input 2: Status
SIWAREX WP321
Operating Instructions, 08/2019, A5E33715669A-AD
Note
Information on which appli‐
cation the data record be‐
longs to
Information on the current
data record version
Cycle counter of the SI‐
WAREX DB incremented
by 1 if process values
have been changed.
Bit 0: QI flag
Bit 1: Load cell input faulty
Bit 2: Checksum error
Bit 3: Checksum error (da‐
ta)
Bit 4: Watchdog error
Bit 5: ADC error
Bit 6: Temperature warn‐
ing
Bit 7: Firmware update er‐
ror
Bit 0: QI flag
Bit 1: Underload
Bit 2: Overload
Bit 3: SEN error
Bit 4: Impedance error
Bit 5: EXC short circuit
Bit 6: Power supply failure
Filtered digit value of AD
converter from SIWAR‐
EX DB to dig. filter 1
Current percentual load of
the load cell in relation to
the rated load of the load
cell
Currently measured load
cell signal
Bit 0: QI flag
Bit 1: Underload
Bit 2: Overload
Bit 3: SEN error
Bit 4: Impedance error
Bit 5: EXC short circuit
Bit 6: Power supply failure
8.19 DR 80 SIWAREX DB process status
Type
Length
Rw
(bytes)
USHORT
2
R
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
LONG
4
r
FLOAT
4
r
Float
4
r
USHORT
2
r
Scale parameters and functions
Default
Min.
Max.
101
-
-
1
1
65635
0
0
0xFFFF
0
-
-
0
-
-
0x7FFF
0x8000
0x7FFF
FFFF
0000
FFFE
0
-200
200
0
-200
200
0
-
-