Mechanical requirements and data
Testing
Vibrational load during op‐
eration
Shock load during opera‐
tion
Vibration load during
transport
Shock load during trans‐
port
Free fall
12.2

Electrical, EMC and climatic requirements

Electrical protection and safety requirements
Fulfilled requirement
Safety regulations
Protection class
IP rating
SIWAREX WP321
Operating Instructions, 08/2019, A5E33715669A-AD
12.2 Electrical, EMC and climatic requirements
Standards
IEC 61131-2
IEC 60068-2-6
Test Fc
IEC 61131-2
IEC 60068-2-27
Test Ea
IEC 60068-2-6
Test Fc
IEC 60068-2-27:
Test Ea
IEC 61131-2
IEC 60068-2-31:
Test Ec, procedure 1
Standards
IEC 61010-1
IEC 61131-2; UL 508
CSA C22.2 No.142
IEC 61010-2-201
FM3611
IEC 61140
IP 20 to IEC 60529
Technical data
Test values
● 5 to 8.4 Hz: 3.5 mm out.
● 8.4 to 150 Hz: 9.8 m/s
● 150 m/s
(approx. 15 g), half sine
2
● 5 to 8.4 Hz: 3.5 mm out.
● 8.4 Hz to 500 Hz: 9.8 m/s
● 250 m/s
(25G), half sine
2
● In product packaging:
300 mm drop height
● In shipping package:
1.0 m drop height
Comments
Module is operated with protective extra-
low voltage.
The protective conductor connection
serves only a functional earth to dissipate
interference currents
● Protection against contact with
standard probe
● Protection against solid bodies with
diameters greater than 12.5 mm
● No special protection against water
(=1G)
2
2