Calibration Digits 0, 1, 2 (Calculated); Dr 5 Zeroing Memory - Siemens SIWAREX WP321 Operating Instructions Manual

Electronic weighing system
Hide thumbs Also See for SIWAREX WP321:
Table of Contents

Advertisement

Variable
Note
Calibration digits 0
(calculated): Calibra‐
Calibration digits
tion digits calculated
0, 1, 2 (calculated)
in "Automatic Calibra‐
(Page 71)
tion"
Calibration digits 1
(calculated): Calibra‐
tion digits calculated
in "Automatic Calibra‐
tion"
Calibration digits 2
(calculated): Calibra‐
tion digits calculated
in "Automatic Calibra‐
tion"
Reserve 1
Reserve
Reserve 2
Reserve
Reserve 3
Reserve
8.6.1

Calibration digits 0, 1, 2 (calculated)

The calculation is based on the parameters from DR 3 and DR 10 identified by bold font and is
activated by the command no. 82.
8.7

DR 5 zeroing memory

Data record DR 5 displays the current values in the tare memory and the zeroing memory.
Procedure
● Check all parameters
● Transfer the data record to the scale
Table 8-3
Assignment of data record 5
Variable
Note
Data record
Contains no. of data re‐
number
cord
Length
Data record length infor‐
mation
Application
Information about which
application the DR be‐
longs to
Version identifi‐
Information on the current
er
data record version
SIWAREX WP321
Operating Instructions, 08/2019, A5E33715669A-AD
Type
L
DINT
4
DINT
4
DINT
4
INT
2
UINT
2
REAL
4
Type
L
UINT
2
UINT
2
UINT
2
UINT
2
Scale parameters and functions
8.7 DR 5 zeroing memory
Rw
Default
Min.
r
?
r
0
r
0
r
0
-
r
0
-
r
0
-
Rw
Default
r
5
r
40
r
201
r
1
Max.
-
-
-
Min.
Max.
-
-
-
-
-
-
1
65635
71

Advertisement

Table of Contents
loading

Table of Contents