Calibration With Calibration Weight - Siemens SIWAREX WP321 Operating Instructions Manual

Electronic weighing system
Hide thumbs Also See for SIWAREX WP321:
Table of Contents

Advertisement

7.4.3.2

Calibration with calibration weight

Define calibration parameters
● Enter the marked and described calibration parameters.
Figure 7-10
Send calibration parameters
● Send the calibration parameters set on your PC to SIWAREX.
● Select "Service mode on" in the Service menu. The calibration parameter (DR3) can only be
sent and the calibration commands executed with service mode switched on.
SIWAREX WP321
Operating Instructions, 08/2019, A5E33715669A-AD
The defined weight unit applies to all weight specifications. You can specify a string with up to 4
digits as the weight unit, e.g.: t, kg, lbs.
Exceeding the maximum weight (= maximum material to be weighed) is indicated in DS30, status
1-2, at parameter "Max 9e". If the maximum weight is exceeded, this bit is set to TRUE.
The resolution d is used for the weight display in the SIWATOOL program. You can set the
resolution d in accordance with EN 45501 (0.0001 to 50).
Calibration weight 1 and its corresponding calibration digits define the characteristic curve of the
scale.
Use a minimum calibration weight as calibration weight 1, with a load cell characteristic value of:
● 1 mV/V: 4 % of the total rated load of all load cells
● 2 mV/V: 2 % of the total rated load of all load cells
● 4 mV/V: 1 % of the total rated load of all load cells
Example
Number of load cells: 3
Nominal load of one single load cell: 100 kg
Load cell characteristic value: 2 mV/V
Use the following minimum calibration weight for calibration:
2 % x 3 x 100 kg = 6 kg
SIWATOOL: Calibration parameters for calibration with calibration weight
7.4 Fast commissioning (Quick Start) with SIWATOOL
Commissioning
47

Advertisement

Table of Contents
loading