Table 11-7 RFI Filter terminal data
CT
Schaffner
part
part
number
number
4200-6104
FS5101-10-07
4200-6105
FS5111-10-29
4200-6108
FS5106-16-07
4200-6109
FS5112-16-07
4200-6113
FS5106-25-07
4200-6114
FS5113-25-29
4200-6116
FS5113-50-53
4200-6117
FS5113-63-34
4200-6106 FS5113-100-35
4200-6107 FS5113-150-40
4200-6111 FS5113-180-40
4200-6112 FS5113-220-37
4200-6115 FS5113-300-99
For all the RFI filters, except the size 5 (4200-6115), the power
connections are screw terminals and the ground connections are stud
terminals
11.1.20
Electromagnetic compatibility (EMC)
This is a summary of the EMC performance of the drive. For full details,
refer to the Unidrive EMC Data Sheet which can be obtained from the
supplier of the drive.
Immunity
Compliance with immunity standards does not depend on installation
details. drives meet EN50082-2 (generic immunity standard for the
industrial environment) and the following specifications from the
IEC61000-4 group (derived from IEC801):
Part 2 Electrostatic discharge: Level 3
Part 3 Radio frequency field:
Part 4 Transient burst
Level 4 at the control terminals
Level 3 at the power terminals
Part 5 Surge (at the AC supply terminals)
(as specified by EN50082-2 informative annex):
Level 4 line-to-ground
Level 3 line-to-line
Part 6 Conducted radio frequency: Level 3
Emission
Compliance with emission standards depends on rigorous adherence to
the installation guidelines, including the use of the specified RFI filter in
the AC supply circuit. Compliance also depends on the PWM switching
frequency used in the output stage of the drive, and the length of the
motor cable. For full details, refer to the Unidrive EMC Data Sheet which
Unidrive User Guide
Issue Number: 9
Electrical
Getting
Menu 0
Installation
Started
Power
Ground
connections
connections
Max
Torque
Size
cable
size
2
0.8 N m
4 mm
M5
7.1 lb in
19.5 lb in
10 AWG
2
0.8 N m
4 mm
M5
7.1 lb in
19.5 lb in
10 AWG
2
0.8 N m
4 mm
M5
7.1 lb in
19.5 lb in
10 AWG
2
0.8 N m
4 mm
M5
7.1 lb in
19.5 lb in
10 AWG
2
0.8 N m
4 mm
M5
7.1 lb in
19.5 lb in
10 AWG
2
0.8 N m
4 mm
M5
7.1 lb in
19.5 lb in
10 AWG
2
4.5 N m
10 mm
M5
3.3 lb ft
19.5 lb in
6 AWG
2
4.5 N m
10 mm
M6
3.3 lb ft
6 AWG
2
8.0 N m
50 mm
M8
5.9 lb ft
1/0 AWG
2
20.0 N m
18.0 N m
95 mm
M10
14.7 lb ft
13.3 lb ft
4/0 AWG
2
20.0 N m
20.0 N m
95 mm
M12
14.7 lb ft
14.7 lb ft
4/0 AWG
2
30.0 N m
20.0 N m
150 mm
M12
22.1 lb ft
14.7 lb ft
6/0 AWG
30.0 N m
M12
20.0 N m
M12 stud
22.1 lb ft
stud
14.7 lb ft
Level 3
www.controltechniques.com
Running
Optimisation
Macros
the motor
can be obtained from the supplier of the drive.
When installed according to the instructions the drive can meet the
emission requirements of CENELEC generic emission standards, as
follows:
Table 11-8 Unidrive emission standards
Torque
Unidrive
EN50081-1
conducted
2.2 N m
1
Restricted
motor cable
2.2 N m
length*
2
Restricted
2.2 N m
motor cable
length*
2.2 N m
3
4
2.2 N m
5
* Compliance with EN50081-1 is restricted to motor cable lengths less
2.2 N m
than 100m.
For compliance the optional RFI filter specified below must be used:
2.2 N m
4.0 N m
Model
2.9 lb ft
9.0 N m
UNI1201 to UNI1205
6.6 lb ft
UNI1401 to UNI1405
UNI2201 to UNI2202
UNI2401
UNI2203
UNI2402 to UNI2403
UNI3201 to UNI3202
UNI3401 to UNI3403
UNI3203
UNI3404
UNI3204
UNI3405
UNI4401 to UNI4402
UNI4403 to UNI4404
UNI4405
UNI5401
Power Drive Systems standard EN61800-3
The drive meets the immunity requirements of EN61800-3 irrespective of
the environment in which it is operating.
The emission requirements of this standard are also met depending on
the environment category, as shown in the table later on this page.
EN61800-3 defines the following:
•
The first environment as one that includes domestic premises. It also
includes establishments directly connected without intermediate
transformers to a low-voltage power supply network which supplies
buildings used for domestic purposes.
•
The second environment is one that includes all establishments
other than those directly connected to a low-voltage power supply
network which supplies buildings used for domestic purposes.
•
Restricted distribution is defined as a mode of sales distribution in
which the manufacturer restricts the supply of equipment to
suppliers, customers or users who separately or jointly have
technical competence in the EMC requirements of the application of
drives.
Advanced
Technical
Parameters
Data
EN50081-1
EN50081-2
radiated
conducted
No
Yes
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
RFI filter
Mounting
CT part
style
number
Footprint or
4200-6104
Bookcase
Bookcase
4200-6105
Footprint or
4200-6108
Bookcase
Bookcase
4200-6109
Footprint or
4200-6113
Bookcase
Bookcase
4200-6114
Bookcase
4200-6116
Bookcase
4200-6117
Bookcase
4200-6106 FS5113-100-35
Bookcase
4200-6107 FS5113-150-40
Bookcase
4200-6111
Bookcase
4200-6112
Bookcase
4200-6115
UL Listing
Diagnostics
Information
EN50081-2
radiated
Yes
Yes
Yes
Yes
Yes
Schaffner part
number
FS5101-10-07
FS5111-10-29
FS5106-16-07
FS5112-16-07
FS5106-25-07
FS5113-25-29
FS5113-50-53
FS5113-63-34
FS5113-180-40
FS5113-220-37
FS5113-300-99
195
Need help?
Do you have a question about the Unidrive 1 Series and is the answer not in the manual?