Control Techniques Unidrive 1 Series User Manual page 144

Universal variable speed ac drive for induction and servo motors
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Parameter
6.01
Stop mode selector*
6.02
Auto-start mode selector
6.03
supply loss mode selector**
AC
6.04
Sequencing mode selector***
6.05
Minimum jog time
6.06
Injection braking level
6.07
Injection braking time*
6.08
Hold zero speed enable*
6.09
Synchronize to a spinning motor****
6.10
Synchronization ramp rate****
6.11
Keypad run key enable
6.12
Keypad stop key enable
6.13
Keypad fwd/rev key enable
6.15
Drive enable
6.16
Electricity cost / kWh
6.17
Power consumption meter reset
6.18
Time interval between filter changes
6.19
Filter change required/done
6.20
Time interval between lubrication
6.21
Lubrication required/done
6.22
Run-time log
6.23
Run-time log
6.24
Power meter
6.25
Power meter
6.26
Running cost
6.27
Time before filter change due
6.28
Time before lubrication due
6.29
Hardware enable
6.30
Sequencing bit 0
6.31
Sequencing bit 1
6.32
Sequencing bit 2
6.33
Sequencing bit 3
6.34
Run permit / not stop
6.35
Limit switch 1
6.36
Limit switch 2
6.37
Spinning motor start-voltage****
6.38
Spinning motor voltage-ramp****
RO
Read Only parameter
RW
Read / Write parameter
NOTE
Where a parameter is represented by a text value, the value in brackets
in the range column is the setting used for serial communications.
* For more information, refer to section 10.22.4 Stop Modes on
page 184.
** For more information, refer to section 10.22.5 Mains loss modes on
page 185.
*** For more information, refer to section 10.22.6 Sequencing Modes on
page 186.
**** For more information, refer to section 10.22.7 Catch a spinning
motor on page 187.
144
Electrical
Getting
Menu 0
Installation
Started
OL
COASt (0), rP (1),
{0.16}
rP-dcI (2), dcI (3),
td.dcI (4)
diS (0), ALYS (1), Pd.dP (2)
diS (0), StoP (1), ridE.th (2)
0 to 100.0 %FLC
0 to 25.0 s
{0.39}
0 to 25.0 s/100Hz
0 to 600.0 Currency/kWh
0 to 30.365 years.days
0 to 32,000 Currency/hr
0 to 100.0 %
0 to 2.5 s
Uni
Unipolar variable parameter
Bi
Bipolar variable parameter
Txt
Text variable parameter
Bit
Bit parameter
www.controltechniques.com
Running
Optimisation
Macros
the motor
Range(
)
CL
COASt (0), rP (1),
no.rP (2), rP-POS (3)
0 to 4
0 to 25.0 s
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 to 30,000 hr
0 or 1
0 to 30,000 hr
0 or 1
0 to 23.59 hr min
0 to 30,000 MWh
0 to 999.9 kWh
0 to 30,000 hr
0 to 30,000 hr
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
R
Reset required for new value to take effect
S
New parameter-value saved at power-down
P
Protected; forbidden as destination parameter
FLC
Full-load current (max. continuous), Pr 11.32 {0.33}
Advanced
Technical
Diagnostics
Parameters
Data
Default(
)
OL
VT
SV
rP (1)
no.rP (2)
RW Txt
diS (0)
RW Txt
diS (0)
RW Txt
4
RW Uni
0.0
RW Uni
100.0
RW Uni
5.0
RW Uni
0
1
RW Bit
0
1
RW Bit
5
RW Uni
0
RW Bit
0
RW Bit
0
RW Bit
1
RW Bit
0
RW Uni
0
RW Bit
0
RW Uni
1
RW Bit
0
RW Uni
1
RW Bit
0
RW Bit
0
RW Bit
0
RW Bit
0
RW Bit
0
RW Bit
25
RW Uni
0.25
RW Uni
Unidrive User Guide
Issue Number: 9
UL Listing
Information
Type
P
P
RO Uni S
P
RO Uni S
P
RO Uni S
P
RO Uni S
P
RO Uni S
P
RO Uni S
P
RO Uni S
P
RO Bit
P
RO Bit
RO Bit

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Unidrive 1 Series and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF