UD50 Additional I/O small option module parameter
list
Parameter
16.01 Option module code
16.02 Relay 2 output indicator
16.03 Relay 3 output indicator
16.04 Analog input 4
16.05 Analog input 5
16.07 Logic input F7 / Output 7 indicator
16.08 Logic input F8 / Output 8 indicator
16.09 Logic input F9 / Output 9 indicator
16.10 Logic input F10
16.11 Logic input F11
16.12 Logic input F12
16.13 Analog input 4 scaling
16.14 Analog input 4 invert bit
16.15 Analog input 4 destination
16.16 Analog input 5 scaling
16.17 Analog input 5 invert bit
16.18 Analog input 5 destination
16.19 DAC Output 3 source
16.20 DAC Output 3 scaling
16.21 F7 input destination / output source
16.22 F7 input/output invert
16.23 F7 output enable
16.24 F8 input destination / output source
16.25 F8 input/output invert
16.26 F8 output enable
16.27 F9 input destination / output source
16.28 F9 input/output invert
16.29 F9 output enable
16.30 F10 input destination
16.31 F10 input invert
16.32 F11 input destination
16.33 F11 input invert
16.34 F12 input destination
16.35 F12 input invert
16.36 Relay 2 source
16.37 Relay 2 output invert
16.38 Relay 3 source
16.39 Relay 3 output invert
16.40 Logic input polarity
16.41 Open collector outputs
RO
Read Only parameter
RW
Read / Write parameter
Unidrive User Guide
Issue Number: 9
Electrical
Getting
Menu 0
Installation
Started
OL
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
Uni
Unipolar variable parameter
Bi
Bipolar variable parameter
Txt
Text variable parameter
Bit
Bit parameter
www.controltechniques.com
Running
Optimisation
Macros
the motor
Range( )
CL
0 to 100
0 or 1
0 or 1
±100.0 %
±100.0 %
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0.000 to 4.000
0 or 1
0.000 to 4.000
0 or 1
0.000 to 4.000
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
R
Reset required for new value to take effect
S
New parameter-value saved at power-down
P
Protected; forbidden as destination parameter
FLC
Full-load current (max. continuous), Pr 11.32 { 0.33 }
Advanced
Technical
Diagnostics
Parameters
Data
Default(
)
OL
VT
SV
1
RO Uni
RO Bit
RO Bit
RO
RO
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
RO Bit
1.000
RW Uni
0
RW Bit
Pr 0.00
RW Uni R
1.000
RW Uni
0
RW Bit
Pr 0.00
RW Uni R
Pr 0.00
RW Uni R
1.000
RW Uni
Pr 0.00
RW Uni R
0
RW Bit
0
RW Bit
Pr 0.00
RW Uni R
0
RW Bit
0
RW Bit
Pr 0.00
RW Uni R
0
RW Bit
0
RW Bit
Pr 0.00
RW Uni R
0
RW Bit
Pr 0.00
RW Uni R
0
RW Bit
Pr 0.00
RW Uni R
0
RW Bit
Pr 0.00
RW Uni R
0
RW Bit
Pr 0.00
RW Uni R
0
RW Bit
0
RW Bit
0
RW Bit
UL Listing
Information
Type
P
P
P
Bi
P
Bi
P
P
P
P
P
P
P
P
P
P
P
R
P
R
P
R
P
P
P
P
P
R
P
R
P
175

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Unidrive 1 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF