Safety
Product
Mechanical
Information
Information
Installation
Parameter
7.01
Analog input 1
7.02
Analog input 2
7.03
Analog input 3
7.04
Heatsink temperature
7.05
Control board temperature
7.06
Analog input 1 mode selector
7.07
Analog input 1 offset trim
7.08
Analog input 1 scaling
7.09
Analog input 1 invert
7.10
Analog input 1 destination parameter
7.11
Analog input 2 mode selector
7.12
Analog input 2 scaling
7.13
Analog input 2 invert
7.14
Analog input 2 destination parameter
7.15
Analog input 3 mode selector
7.16
Analog input 3 scaling
7.17
Analog input 3 invert
7.18
Analog input 3 destination parameter
7.19
Analog output 1 source parameter
7.20
Analog output 1 scaling
7.21
Analog output 1 mode selector
7.22
Analog output 2 source parameter
7.23
Analog output 2 scaling
7.24
Analog output 2 mode selector
7.25
Calibrate analog input 1 full scale
7.26
V/f sample time
Analog input 1 current-loop loss
7.27
indicator
Analog input 2 current-loop loss
7.28
indicator
Analog input 3 current-loop loss
7.29
indicator
7.30
Analog output set-up enable
UD78 large option module fitted
7.31
indicator
7.32
IGBT junction temperature
RO
Read Only parameter
RW
Read / Write parameter
NOTE
Where a parameter is represented by a text value, the value in brackets
in the range column is the setting used for serial communications.
146
Electrical
Getting
Menu 0
Installation
Started
OL
VOLt (0), 0 - 20 (1), 20 - 0 (2), 4 - 20.tr (3),
{0.24}
20 - 4.tr (4), 4 - 20.Lo (5), 20 - 4.Lo (6),
4 - 20.Pr (7), 20 - 4.Pr (8)
Pr 0.00 to Pr 20.50
{0.25}
{0.26}
Pr 0.00 to Pr 20.50
VOLt (0), 0 - 20 (1), 20 - 0 (2), 4 - 20.tr (3) ,
20 - 4.tr (4), 4 - 20.Lo (5) , 20 - 4.Lo (6),
4 - 20.Pr (7), 20 - 4.Pr (8), th.SC (9), th (10)
Pr 0.00 to Pr 20.50
Pr 0.00 to Pr 20.50
VOLt (0), 0 - 20 (1), 4 - 20 (2)
Pr 0.00 to Pr 20.50
VOLt (0), 0 - 20 (1), 4 - 20 (2)
Uni
Unipolar variable parameter
Bi
Bipolar variable parameter
Txt
Text variable parameter
Bit
Bit parameter
www.controltechniques.com
Running
Optimisation
Macros
the motor
Range( )
CL
±100.0 %
±100.0 %
±100.0 %
o
0 to 100
C
o
0 to 100
C
±10.000 %
0 to 4.000
0 or 1
(as Pr 7.06)
0 to 4.000
0 or 1
0 to 4.000
0 or 1
0 to 4.000
0 to 4.000
0 or 1
0 to 5.0 ms
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 to 150 °C
R
Reset required for new value to take effect
S
New parameter-value saved at power-down
P
Protected; forbidden as destination parameter
FLC
Full-load current (max. continuous), Pr 11.32 {0.33}
Advanced
Technical
Diagnostics
Parameters
Data
Default(
)
OL
VT
SV
VOLt (0)
0
1.000
0
Pr 1.36
VOLt (0)
1
0
Pr 1.37
EUR> th (10), USA> VOLt (0)
1.000
0
Pr 0.00
Pr 5.01
Pr 3.02
1
VOLt (0)
Pr 4.02
1.000
VOLt (0)
0
4.0
0
Unidrive User Guide
Issue Number: 9
UL Listing
Information
Type
RO
Bi
P
RO
Bi
P
RO
Bi
P
RO Uni
P
RO Uni
P
RW Txt R
RW Bi
P
RW Uni
RW Bit
RW Uni R
P
RW Txt R
RW Uni
RW Bit
RW Uni R
P
RW Txt R
RW Uni
RW Bit
RW Uni R
P
RW Uni R
P
RW Uni
RW Txt R
P
RW Uni R
P
RW Uni
RW Txt R
P
RW Bit
RW Uni
RO Bit
P
RO Bit
P
RO Bit
P
RW Bit
RO Bit
P
RO Uni
P
Need help?
Do you have a question about the Unidrive 1 Series and is the answer not in the manual?