Procedure:
1. Unscrew union nut 1 from gun housing 4.
2. Pull flat jet nozzle 2 off electrode holder 3.
3. Carefully pull electrode holder 3 out of the gun housing 4.
Note:
Do not damage the electrode holder 3, when pulling it
out and inserting it.
4. Remove powder residues from the removed parts and
from the automatic gun.
5. Carefully fit the new C4 R electrode holder 5 into gun
housing 4.
6. Slide deflector cone sleeve 6 onto electrode holder 5.
7. Align the X and Y marks.
8. Fasten union nut 1.
9. Slide deflector cone 7 over deflector cone sleeve 6.
10. The spray gun is ready for use again.
8.7

ASSEMBLING THE ANGLE ADAPTER

8.7.1 REMOVING THE NOZZLE AND ELECTRODE HOLDER

The standard automatic gun is delivered with a flat jet nozzle. The nozzle can be changed easily,
as described below.
Note:
If changing from the flat jet nozzle to the deflector cone, the depth control must be adjusted.
A WA90 C4, WA 60 C4 or WA30 C4 angle adapter is necessary to perform the change, as
listed in Chapter 12.
Note:
A flat jet nozzle as well as a round jet nozzle can be fitted to the angle adapter.
ORDER NUMBER DOC390829
PEA-C4-HiCoat
3
2
1
P_03907
5
6
6
1
7
Y
P_03914
4
4
X