Maintenance And Repair; Protective And Monitoring Equipment - WAGNER PEA-C4-HiCoat Translation Of The Original Operating Manual

Automatic powder gun
Table of Contents

Advertisement

VERSION 05/2019

4.2.7 MAINTENANCE AND REPAIR

Danger due to improper maintenance and repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
Use only WAGNER original spare parts and accessories.
Do not change or modify the device; if change is necessary, contact WAGNER.
Only repair and replace parts that are listed in Chapter
assigned to the device.
Do not use any defective components.
Before all work on the device and in the event of work interruptions:
– Switch off the energy and compressed air supply.
– Relieve pressure on powder spray gun and device.
– Secure the powder spray gun against actuation.
Observe the operating and service manual for all work.

4.2.8 PROTECTIVE AND MONITORING EQUIPMENT

Danger due to removal of protective and monitoring equipment!
Danger to life and equipment damage.
Protective and monitoring equipment must not be removed, modified or rendered
unusable.
Regularly check for perfect functioning.
If defects are detected on protective and monitoring equipment, the system must
not be operated until these defects are remedied.
4.2.8.1 RELEASING GUNS (HIGH VOLTAGE/PNEUMATIC SYSTEM)
Enabling high voltage depends on:
– Exhaust air is OK
– Fire extinguishing system/fire detection signal OK (external signal)
– No EMERGENCY STOP
– Control voltage ON
As soon as one of these conditions is not fulfilled, the high voltage is switched off
immediately. After the fault has been eliminated and acknowledged, the enabling
mechanism can be selected again. An automatic switch on is prevented by the hardware
locking.
ORDER NUMBER DOC390829