Grounding The Powder Coating System; Safety Checks - WAGNER PEA-C4-HiCoat Translation Of The Original Operating Manual

Automatic powder gun
Table of Contents

Advertisement

VERSION 05/2019

6.6.1 GROUNDING THE POWDER COATING SYSTEM

4
1
5
P_01614
1 Only use mains cables with grounding strand!
2 Connect the control unit's grounding cable with the signal ground!
3 Remove all paint from hooks and other hanger parts!
4 Wear electrostatically conductive gloves!
5 Wear electrostatically conductive footwear!
6 The floor must be electrostatically conductive!
6.7

SAFETY CHECKS

A skilled person must check to ensure that the device is in a reliable state after it is assembled
and commissioned.
This includes:
– Carry out safety checks in accordance with Chapter 8.2.3.
ORDER NUMBER DOC390829
2
6
PEA-C4-HiCoat
3
26