6.6.1 GROUNDING THE POWDER COATING SYSTEM
4
1
5
P_01614
1 Only use mains cables with grounding strand!
2 Connect the control unit's grounding cable with the signal ground!
3 Remove all paint from hooks and other hanger parts!
4 Wear electrostatically conductive gloves!
5 Wear electrostatically conductive footwear!
6 The floor must be electrostatically conductive!
6.7
SAFETY CHECKS
A skilled person must check to ensure that the device is in a reliable state after it is assembled
and commissioned.
This includes:
– Carry out safety checks in accordance with Chapter 8.2.3.